My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00529-PERMIT VOIDED
Orono
>
Property Files
>
Street Address
>
G
>
Graham Hill Road
>
3315 Graham Hill Road - 05-117-23-11-0007
>
Permits/Inspections
>
2009-00529-PERMIT VOIDED
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:16 PM
Creation date
1/12/2017 2:15:30 PM
Metadata
Fields
Template:
x Address Old
House Number
3315
Street Name
Graham Hill
Street Type
Road
Address
3315 Graham Hill Rd
Document Type
Permits/Inspections
PIN
0511723110007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> �=Part �. DEPRESSlJRIZATION Pl�OTECTIOIiT <br /> Cl;eck option used: � Puel btu-ning equipment (complete schedules below) ❑ No fuel burning equipment <br /> INsrRucrioNs EXHAUST/MAKG-UP AIR SCHEDULE* <br /> Step 1. Complete the Combustron L'quipment Schedule below. Only equipment Exhaust devices over 300 cfin Flow - <br /> with a Y (Yes)may be selected under the"Category 1"alternate. cfrn <br /> Step 2. Complete Exlaaust/Mnl:e-up Air Schedule on tl�e right if direct or power cfni <br /> vented or solid fuel atmospheric vent space heating equipment is cfiii <br /> selected. <br /> COMBUSTION.EQUIPMENT SCHEDULE <br /> ' - (check all types proposed) <br /> Space heatiiig—noiisolid fue] Sea]ed combustion—Z Y Heai•th = nonsolid fuel � Sealed combustion <br /> ❑ Direct or po��er vented L�- ❑ Direct or power vented Y'_' <br /> - Y�; <br /> ` Atmos herically veirfed N - Atmos liei�ically vented N <br /> Water heating noiisolid fuel ❑ Sealed combustion Y Space heating-solid fuel ❑ Atmospherically vented <br /> _ I,*., <br /> Direct �power vented Watei heatin -solid fuel ❑ Atmos herically vented Y <br /> ` ;Atmo§phenca y,vented N. Hearth-solid fiiel ❑ Atmospherica]ly vented ' Y <br /> * If atinospherically vented solid fuel or,d'u•ect'or power vented nonsolid,fuel Space heating is installed, then make-up`air to ii�atcli <br /> f3ow is required for each individual exl�aust device which exceeds 300 cuUic feet per minute. <br /> Part C1. VENTILATION <br /> V_ENTLLATION QUANTITY: - - <br /> (IvIechanical ventilation must be provided per the larger quantity`calculated Ue]ow) - <br /> �SO Z� 'cubic feef s 0.00583/minute = � cfm ('Cs x 15 cfm/bedroom)+15 cftn= �17� cfm` <br /> volume of habifable rooms - number of bedrooms <br /> - . 'VENTILATIONFAN_SCI3EDULE <br /> Check method(s)proposed 3 _[_0 Exhaust only Balanced (heat iecoveiy ventilator,air exchanger, etc.) <br /> Fan descri tion or location '� p� Z. .�.4- AT� S TCI��L'�l TOTALS . < <br /> VENTILATION Intake cfin . cfni, cfin QO cfm` (of� ; cfm` <br /> AS DESIGNED- Exliaust p :cfin' ZID cfni �p cfm' cfiri` 'cfrii. <br /> St?t�mCP_t of Corr�nli�nc.e: The proposed building design represented in these documents is consistent with the building plans, <br /> specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet tl�e <br /> requirements of the Minnesota Energy Code. o <br /> S�vE L�cN� �u�� B-ZI-6� G/Z- 3S%-/7O9 <br /> Applicant(print natne) Signature Date Telephone i�tunber <br /> Part C2. VENTILATION (Submit Part C2 upon completion of system verification�) <br /> 4/ <br /> �� ------------------------------ ------ ------------------------- <br /> Job Site Address: Pernlit Number <br /> Fan`descri tiori or location _ TOTALS <br /> IVIEASURED ', Intake: cfin cfni cfin cfm cfin <br /> PERFORMANCE-� Ezhausf cfm cfiu : cfm cfin`� cfni <br /> -� : Ventilation rate must_be �neasured and verified wlien the performance option is used in lieu of the prescriptive option for the <br /> sealing of joints in the biiilding conditioiied envelope(from Part A). ' <br /> Compliance Statement: Installed ventilation system is in compliance with MN Energy Code and is sized to provide the design air <br /> fl ow. <br /> Applicant(print name) Signature Date Telephone number <br />