Laserfiche WebLink
, <br /> �✓apor Retarder: <br /> , u Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors;or it has been determined that <br /> moisture or its freezing will not damage the materials;or other approved means to avoid condensation are provided. <br /> Comments: <br /> Materials Identification: <br /> � Materials and equipment are identified so that compliance can be determined. <br /> U Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. <br /> � Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. <br /> u Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner <br /> that achieves the rated R-value without compressing the insulation. <br /> Duct Insulation: <br /> J Ducts in unconditioned spaces or outside the building are insulated to at least R-8. <br /> U Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6. <br /> Duct Construction: <br /> � Air handlers,filter boxes,and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and <br /> mechanically fastened. <br /> U All joints,seams,and connections are made substantially airtight with tapes,gasketing,mastics(adhesives)or other approved closure <br /> systems.Tapes and mastics are rated UL 181A or UL 181 B. <br /> U Building framing cavities are not used as supply ducts. <br /> � Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. <br /> u Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International <br /> Mechanical Code. <br /> Temperature Controls: <br /> � Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or <br /> cooling input to each zone or floor is provided. <br /> Heating and Cooling Equipment Sizing: <br /> U Additional requirements for equipment sizing are included by an inspection for compliance with the International Mechanical Code. <br /> Circulating Hot Water Systems: <br /> U Circulating hot water pipes are insulated to R-2. <br /> � Circulating hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not <br /> in use. <br /> Heating and Cooling Piping Insulation: <br /> U HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2. <br /> Certificate: <br /> U A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window <br /> U-factors;type and efficiency of space-conditioning and water heating equipment. <br /> NOTES TO FIELD:(Building Department Use Only) <br /> J _._ _ _ _ Report date: 12/31/08 <br /> Pro ect Title: WEBER HOUSE <br /> Data filename:C:1Program Files\Check\REScheck\weber house.rck Page 4 of 4 <br />