Laserfiche WebLink
M R - �P�� s' . . � . <br /> � �.���� � <br /> „�. � <br /> �\��?yr +�j c�� > Mi <br /> \��\� <br /> REScheck So#tware Version 4.1.4 <br /> � � Compliance Certificate <br /> Project Title: WEBER HOUSE <br /> Report Date: 12/31/08 <br /> Data filename: C:\Program Files\Check\REScheck\weber house.rck <br /> Energy Code: 2006 IECC <br /> Location: Orono, Minnesota <br /> Construction Type: Single Family <br /> Building Orientation: Bldg.faces 0 deg.from North <br /> Conditioned Floor Area: 6092 ft2 <br /> Glazing Area Percentage: 11% <br /> Heating Degree Days: 8037 <br /> Climate Zone: 6 <br /> Construction Site: Owner/Agent: Designer/Contractor: <br /> 3225 Graham Hill RD <br /> Orono, MN 55356 <br /> Permit Date: 12/31/08 <br /> � :�::�::.��.. s <br /> Compliance:10.2%Better Than Code Maximum UA:687 Your UA:617 <br /> �u <br /> t: - e e <br /> s � i t• <br /> Ceiling 1 Flat Ceiling or Scissor Truss 2367 44.0 1.8 62 <br /> Wall 1:Wood Frame, 16"o.c. 5008 19.0 4.0 222 <br /> Orientation: Unspecified <br /> Window 1: Metal Frame:Double Pane with Low-E 536 0.280 150 <br /> SHGC:0.44 <br /> Orientation: Unspecified <br /> Door 1:Solid 106 0.280 30 <br /> Orientation:Unspecified <br /> Door 2:Glass 104 0.280 29 <br /> SHGC:0.44 <br /> Orientation: Unspecified <br /> Wall 2:Wood Frame,24"o.c. 802 15.0 4.0 50 <br /> Orientation: Unspecified <br /> Basement Wall 1:Solid Concrete or Masonry 594 5.0 1.0 49 <br /> Orientation: Unspecified <br /> Wall height:9.0' <br /> Depth below grade:8.0' <br /> Insulation depth:9.0' <br /> Basement Wall 2:Solid Concrete or Masonry 76 5.0 1.0 8 <br /> Orientation: Unspecified <br /> Wall height:4.0' <br /> Depth below grade:3.6' <br /> Insulation depth:4.0' <br /> Floor 1:All-Wood Joist/Truss:Over Outside Air 487 38.0 0.8 13 <br /> Floor 2:All-Wood JoisUTruss:Over Outside Air 160 41.0 3.0 4 <br /> Furnace 1:Forced Hot Air 92 AFUE <br /> Air Conditioner 1:Electric Central Air 13 SEER <br /> Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other <br /> calculations submitted with the permit application.The proposed building has been designed to meet the 2006 IECC requirements in <br /> REScheck Version 4.1.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. <br /> _, _ <br /> Project Title: WEBER HOUSE Report date: 12/31/08 <br /> Data filename: C:\Program Files\Check\REScheck\weber house.rck Page 1 of 4 <br />