My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P09267 - new septic system
Orono
>
Property Files
>
Street Address
>
G
>
Golden View Drive
>
175 Golden View Drive - 33-118-23-43-0025
>
Septic
>
2005-P09267 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:25 PM
Creation date
12/30/2016 12:17:08 PM
Metadata
Fields
Template:
x Address Old
House Number
175
Street Name
Golden View
Street Type
Drive
Address
175 Golden View Drive
Document Type
Septic
PIN
3311823430025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �7-P TEST/NG� INC• Steven B. Schirmers • MPCA Cert.No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566 <br /> � FAX (763) 497-5011 <br /> State License #394 <br /> ����_. <br /> C�\Z �`�� - SS/� <br /> September 9, 2005 <br /> Vintage Builders <br /> 175 Golden View Dr. <br /> Orono, Henn. Co., MN <br /> A Compliance Inspection was completed for the existing mound system located on this <br /> property. The mound is for a 3 bedroom home & two bedrooms are being added. Soil <br /> borings #1 & 3 found mottled soil (redox features) at 16" in boring #3 at the north end & <br /> 18" at boring #1, the south end. With the bottom of the rock at elev. 101.2, .9' of sand <br /> was found at the south end & 1.9' of sand was found at the north end of the mound. <br /> With mottled soil at 18" at the south end of the mound, 1.5' of sand would be needed to <br /> meet the required 3' separation from the bottom of the rock &the mottled soil. The <br /> system is classified as non-compliant. <br /> To bring the system into compliance the existing 10'x40' rock bed 8� a minimum of 6" of <br /> sand wi�l need to be removed & the topsoil on the south end be removed to the clean <br /> sand. Replace the sand & add to the south end as shown in the design. <br /> The existing tanks are 3-1000 gallon tanks are acceptable to the City Inspector. The <br /> tanks must be water tight. <br /> The existing pump may be used if it meet the requirement for 20' of head pressure & 47 <br /> gal/min. <br /> All neighboring wells are located greater than 100' away from the proposed treatment <br /> area. <br /> ���� . ' <br /> Steven B. Schirmers <br /> 1 <br />