Laserfiche WebLink
�o�, <br /> � � �� <br /> /� _ � <br /> / � <br /> I� �-�;� .�-�: ��� CIT�' of �RONO <br /> I�1 � ,�; �r,s.�— �, �I <br /> \',\'�,+ n�� ati jt �:'' lr,� /�� Municipal Offices <br /> � , <<;;� � �` .,� Gti;�; <br /> ,L � . � ��''.'���` ,� ;,;� Street Address: q5a'a4q'�6� � Mailing Address: <br /> , `9 � ` 4�' 2750 Kelley Parkway P.O. Boz 66 <br /> \I�ESH�:-;.-'-, <br /> ��--�' Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��� �%���' '���-��r +-�f - �'��-% <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> e <br /> SYSTEM C0�IFORMITY (1-31: ' <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cunent Orono <br /> Muaicipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COi�IPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or consh-uction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand beriveen the distribution device and the limiting soi]characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped� - `-1 —i�:A�, ). <br /> Make sure septic tanks are pumped throuQh manhole and not through white inspection pipes. This allows for the proper <br /> cleanina Keep water softner and iron filter dischar�e out of septic svstem to prolonQ life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia.pipe)must be instatled in each tank. If <br /> tanlcs have not been pumped out within the last three years,they should be pumped out now. <br /> DRAII�'FIELD C0�IDITION(8-10): .`� <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing, not critical yet. <br /> 10 Drainfield is saturated and visibly dischar�ing untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> 9 <br /> �COMiv1ENTS: -�C�� :�� �� � /��' �' � <br /> �'� . ''�+���'',,f����-.�.�', :�,.�r �9t,��-�'�� <br /> 7- � > ���� . <br /> Date of Inspection Septic System Inspector <br />