My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01192 - retaining wall
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1285 French Creek Drive - 10-117-23-32-0007
>
Permits/Inspections
>
2016-01192 - retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:30 PM
Creation date
12/27/2016 2:24:42 PM
Metadata
Fields
Template:
x Address Old
House Number
1285
Street Name
French Creek
Street Type
Drive
Address
1285 French Creek Drive
Document Type
Permits/Inspections
PIN
1011723320007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•� � <br /> ' 6 4 5 2 3 <br /> W4 W4 W4 W4 W4 <br /> 963 —963 963 963 <br /> WALL 2 TIES INTO <br /> 962 WALL I AT —962 962 TOP OF WALL GRADE BEHIND WALL 96Z <br /> 961 STA 0+08 t —961 961 961 L E G E N D <br /> 960 —960 960 96U <br /> TOP OF WALL <br /> 959 —959 959 959 <br /> 958 —958 958— � —' -- — — — _ 958 WX - INDICATES CROSS-SECTION TO <br /> 957 GRADE BEHIND WALL —957 957— BASE OF WAIL <br /> —q57 BE USED (SEE SHEET W4) <br /> 956 —956 956— FINiSHED GRADE AT BASE —956 <br /> 955 � � —955 955� I I I �955 <br /> 954 � ' —954 <br /> � o 'n o �n � <br /> 953 � -- � � � —953 0 0 0 0 0 <br /> 952 - - - - � � BASE OF WALL —952 Q Q Q Q Q <br /> 951— FINISHED GRADE AT BASE —951 N N N N N <br /> 950� I I �95o BOULDER WALL - ELEVATION VIEW <br /> o � o � o <br /> 2 WALL 2 (MAX. BEARING PRESSURE = I 000 PSF) <br /> O O � � N N N) <br /> 0 0 0 0 0 0 o W3 (SCALE: I"=5'-0") <br /> Q Q Q Q Q Q Q <br /> F- � F- ►- F- � � <br /> (n tn (n N (n tn tn <br /> BOULDER WALL - ELEVATION VIEW <br /> � WALL I (MAX. BEARING PRESSURE = I 500 PSF) WALL 2, STA o+oo <br /> W3 (SCALE: I"=5'-0") <br /> WALL I, STA 0+00 <br /> NOTES <br /> I) GRADES SHOWN ARE APPROXIMATE, AND MAY VARY IN THE EXISTING HOUSE <br /> FIELD AT THE TIME OF CONSTRUCTION. MINOR ADJUSTMENT <br /> OF THE TOP AND BOTTOM OF WALL ELEVATIONS IS <br /> PERMISSIBLE, PROVIDING THE CROSS-SECTIONS INDICATED ARE <br /> FOLLOWED. SEE SHEET W4 FOR CROSS-SECTION INFORMATION. <br /> 2) MINIMUM EMBEDMENT IS SHOWN ON THE CROSS-SECTIONS. <br /> EXTRA EMBEDMENT IS ALLOWED IF NEEDED TO ACCOMODATE BOULDER WALL <br /> BOULDER SIZES. 3 WALL LOCATION SKETCH <br /> W3 (NOT TO SCALE) <br /> PROPOSED BOULDER RETAINING WALLS SCALE: O I SHEET: OF: /- CLIENT: <br /> �/ic�Cer� �n�ineerii�� � Consu�tin�, LLC 12g5 FRENCH CREEK DRIVE � � W3 `+ SOUTHVIEW DESIGN <br /> AS VERIFY LINE ABOVE MEASURES I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATIONS, OR <br /> 14441 �/illa�e�Ioods�rive ORONO M I NNESOTA I-INCH. IF IT DOESN'T, ADJUST <br /> , REPORT WAS PR RED Y ME OR R MY D ECT <br /> �c�en Prairie, MN 55347 WALL ELEVATI ONS / WALL LOCATION SKETCH SHOWN SCALE ACCORDINGLY SUPERVISION A H A DUL ICE ED P FESSIONAL <br /> Fhone: 952-465-8272 ENGINEER D R A S HE ST MINNESOTA. <br /> REV. N0: DATE: DESCRIPTION: VEC PROJECT N0: VEC 16-228 <br /> www.vickeryen�.com DRAWN BY: RWV <br /> REVIEWED BY: VEC RONALD cKE <br /> �o i�-�'�,L��y t � <<< .ti�.o�,.�,lr���,.,�<<C- <br /> DATE: 9/23/16 DA7E: 9/23 REG. No.: 24065 <br />
The URL can be used to link to this page
Your browser does not support the video tag.