My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003-P06456 - repair septic system
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1285 French Creek Drive - 10-117-23-32-0007
>
Septic
>
2003-P06456 - repair septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:26 PM
Creation date
12/27/2016 2:20:50 PM
Metadata
Fields
Template:
x Address Old
House Number
1285
Street Name
French Creek
Street Type
Drive
Address
1285 French Creek Drive
Document Type
Septic
PIN
1011723320007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�I1S SYSTEM IS DESIGNED fOR <br /> ,�j.,8E0R00A�S. ANY tNCREASE tN NUMBER <br /> ���GI��li�i iWS t�ESIG�. <br /> The 1st existing 1000 gallon tank will be used as a trash trap. The 2nd 1000 gallon <br /> tank will have a pump installed which will pump 19 gallons every 30 minutes to the <br /> Multi-Flo using a timer. The effluent will then flow gravity back to the existing pumping <br /> chamber which will pump to the trenches. The existing trenches must be opened up <br /> and jetted to remove as many solids as possible. If this has already been completed it <br /> does not have to be done again. <br /> A water meter must be installed to monitor the daily water use. <br /> Inspection pipes must be installed to monitor at each trench. <br /> All neighboring wells are located greater than 100' away from the proposed treatment <br /> area. <br /> Nothing other than human waste, toilet tissue, laundry, showers, water softener etc. <br /> should be disposed of into the septic tanks. Iron filters must be diverted out of the <br /> system. Recommend to divert the water softner also. Garbage disposals are not <br /> recommended, due to adding more solids &fine solids passing through to the system. <br /> Excessive amounts of soaps, anti-bacterial soaps, cleaning agents, shower cleaners <br /> used every shower & chlorine agents may kill the bacteria needed to treat septic <br /> effluerit. Additives are not recommended. The trash trap, Multi-Flo and pumping <br /> ,chamber will need to be pumped out when the setable solids reach 50% in the unit. <br /> �his will be determined at the time of the services. <br /> C���- . <br /> Steu�n B. Schirmers <br /> 2 <br />