2014-00673 - plumbing
Orono
>
Property Files
>
Street Address
>
G
>
Glendale Cove Lane
>
2385 Glendale Cove Lane- 34-118-23-33-0069
>
Permits/Inspections
>
2014-00673 - plumbing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:57:11 PM
Creation date
12/20/2016 3:05:50 PM
Metadata
Fields
Template:
x Address Old
House Number
2385
Street Name
Glendale Cove
Street Type
Lane
Address
2385 Glendale Cove Lane
Document Type
Permits/Inspections
PIN
3411823330069
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, s <br /> Wood floor&wall framing by others <br /> „Connection of floor members to sill plate to <br /> be per Code by others <br /> „2x6 minimum sill plate w/1/2"diameter <br /> anchor bolts w/7" minimum embed&2" <br /> wide x 1/8"thick square or round <br /> countersunk washers or alternative anchor <br /> � �° m° (Anchor bolt clearance between edge of <br /> � both wall and sill plate is to be 2.5")(see <br /> table below for spacing) <br /> Grade to be at least 6"below top of wall <br /> ' Exterior top of wall may have a brick ledge <br /> provided the stem wall formed is at least 6" <br /> thick&no more than 16" high <br /> � - Continuous#4 horizontal bars, provide at <br /> � � least(2)@ 8'-0"clear,(3)@ 9'-0"clear, & <br /> _ �� (4)@ 10'-0"clear,At contractor's option: <br /> cu ' � The lowest wall horizontal bar may be <br /> a� <br /> v omitted if(2)#4 continuous horizontal bars <br /> �� � are placed in the footing <br /> ' Cast-in-place concrete foundation wall w/ <br /> #6 or equivalent vertical bars placed 1.5" <br /> from inside face, see table below for <br /> spacing <br /> --. - #4 x 2'-0" long dowels @ 72"o.c. max w/ <br /> 5" minimum embed <br /> � 8" minimum thick unreinforced concrete <br /> strip footing, required width to be <br /> determined per Code by others, elevation <br /> below slab may vary <br /> BASEMENT WALL DETAIL <br /> Clear Height and Soil Type Table Notes: <br /> Wall 8'or Less 9' 10' (1)= Unreinforced if concrete is 4000 psi or if <br /> Thickness Sand SC Clay Sand SC Clay Sand SC Clay clear height is 4"less <br /> Vertical Rebar Spacing (2)= Unreinforced if concrete is 5000 psi or if <br /> 8" NA NA 36"(1) NA 36"(2) 36" 36"(1) 36" 24" clear height is 4"less <br /> 10" NA NA NA NA NA 36"(1) NA 36"(1) 36" Allowed alternate anchors are: <br /> 12" NA NA NA NA NA NA NA NA NA MAB/ST, MASA/FA3, FWAZ,or 1/2"diameter <br /> Sill Anchor Spacing expansion bolts w/6"min embed(install in <br /> Bolts 72" 72" 48" 72" 48" 36" 60" 36" 24" accordance with the manufacturer's <br /> Alternate 48" 24" 18" 36" 18" 12" 24" 12" 8" recommendations) <br /> Oswell Engineering and Consulting, L.L.C. 1901 E Hennepin Ave,#201 ��a � �`„�� r ;�'° <br /> Project Name: 2014 Standardized Concrete Foundation Drawings Minneapolis, MN 55413 '� <br /> Description: Full Height Wall Detail(NOT TO SCALE) Phone: 612-720-4639 q �'� <br /> Project# 13.100 Fax: 612-886-2966 �' � <br /> � <br /> Client Name: Abfalter Brothers Concrete LLC www.oswellec.com ` <br /> + <br /> Client Address: 15546 Cleveland Street, Elk River, MN 55330 Page S6 of S6 � -"`" `� �� ���� <br /> 1/1/2014 <br />