My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-00901 - new structure
Orono
>
Property Files
>
Street Address
>
G
>
Glendale Cove Lane
>
2365 Glendale Cove Lane - 34-118-23-33-0068
>
Permits/Inspections
>
2012-00901 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:57:08 PM
Creation date
12/20/2016 2:01:39 PM
Metadata
Fields
Template:
x Address Old
House Number
2365
Street Name
Glendale Cove
Street Type
Lane
Address
2365 Glendale Cove Lane
Document Type
Permits/Inspections
PIN
3411823330068
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, • ' � <br /> New Construction Energy Code Compliance Certificate • . <br /> Per N I 101.8 Building Certiticate A building certificate sl�all be posted in a pennanently visible location inside Da�e Certiticate Posted <br /> the building. l he certiticate shall be completed by�he builder and shall list infonnation and values of <br /> components listed in Table NI 101 8 $�27��2 <br /> MailingAdAresso(UieDNellingorDwellingUnit Ci[y RICHMOND II <br /> 2365 Glendale Cove Lane Orono <br /> NAme of Kesiden�ial ConlrAclor MN License Nwnber <br /> Youngfield Homes BC627670 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type: CheCk All That Apply X Passive(No Fan) <br /> o v <br /> c <br /> ai v <br /> a y Active(With fan and monometer or <br /> F' a� <br /> ro >, other syslem monrioring device) <br /> Cd V � � � y <br /> C a <br /> �o cz. 3 Y U — o .a ro <br /> y a. o � y .n a� � <br /> o Q c0 co � `, � � �, <br /> `° � o h � o a� i..�, ° <br /> Insulation Location � � z � � U �' � _ <br /> � ' � �p � � � <br /> `° `o � ,- ti �o -o <br /> � � � � p ? � � oL bU <br /> F � z w U. �:. n°. � � cG Other Please Describe Here <br /> I3clow Entire Slab X <br /> Foundation�Vall R-10 X 1-3/8"- 1-1/2" POLYURETHANE <br /> Perimeter of Slab on Grade x <br /> Rim Joist(Foundation) R-13.5 X BASF 178 <br /> Rim Joist(ls'Floor+) R-13.5 X BASF 178 <br /> W'all R-19 X GUARDIAN FIBERGLASS <br /> Ccilin�,tlat R-44 X GUARDIAN FIBERGLASS <br /> Cciling,vAulted R-38 X GUARDIAN FIBERGLASS <br /> 13ay Windows or cantilevereU areas X <br /> 13onus room over gara;;c X <br /> Dcscribc uthcr insulatcd areas All windows & doors - non expanding window hoam - Hilti Foam <br /> Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Avcragc U-Factor(esdiides sln�lights and one door)U: �.3 1 X Not applicable,all ducts locatcd in conditioned space <br /> Solar Heat Gain Coefticient(SI IGC): 0.29 <br /> MECHANICAL SYSTEMS Make-up Air Select a 7j�pe <br /> ApplianCeS Heatina System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type NATURAL ELECTRIC Electrie Passive <br /> Nlanufacturer Trane RHEEM Trane Powered <br /> Interlocked with exhaust device. <br /> Mode1 TuC1C100 MARATHON 4ttb3036 Describe: <br /> Input in ���,00� Capacity in ��S Outpu[in 3 Other,describe: <br /> Kating or Si'te [3TUS Gallons: Tons: <br /> Heat�oss: �� 3�2 Heat Ga�„� 33,751 Location of duct or system: <br /> Structure's Calculated <br /> nFue o� q2o/a sFEa� I 3 <br /> i is�>Fe%�, <br /> c�i���i���a 33,751 <br /> Efticicnc � cooling load: Ct�m's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systcros if installed:(e.g.two furnaces or air Combustion Air Selecl a Tvpe <br /> source heat pump with gas back-up t�urnace): X Not rcquircd per mech.code <br /> Select Type Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: I�igh: Location of duct or system: <br /> X Continuous exhausting fan(s)rated capacity in cfms: 130 cfm <br /> Location of fan(s),describe: Main Bath Cfin's <br /> Capacity intermittent ventilation rate in efms: ��� "round duct OR <br /> Total ventilation(intennittent+continuous)rate in cfms: 24� "metal duct <br /> rea e y version <br />
The URL can be used to link to this page
Your browser does not support the video tag.