My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
08-08-2016 Council Packet
Orono
>
City Council
>
2016
>
08-08-2016 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2016 3:22:34 PM
Creation date
12/16/2016 3:14:35 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br />Rezoning. The development is based on RPUD zoning, which allows for flexibility in design necessary <br />to meet goals of the comprehensive plan. The chart below highlights the flexibility necessary. The only <br />change in the chart is the FAR increased to 0.43, reflecting a 3,400 square foot home, still below the <br />standard.??? <br /> <br /> RPUD District Minimum <br />SFR Standard <br />Proposed <br />Lot Standards <br />Flexibility <br />Required? <br />Minimum project size: 5 acres 2.34 acres Yes <br />Minimum lot size: 15,000 square feet 7,800 s.f. – 61,400 <br />s.f. (incl. wetlands) <br />4 of 7 lots < 15,000 <br />s.f. <br />Yes <br />Minimum lot width at setback <br />line: <br />90 feet 50’ min and typical/ <br />70 ft widest <br />Yes <br />Minimum lot depth: 125 feet Varies - all 150’ + No <br />Minimum front building <br />setback: <br />25 feet 20’ feet min. (25’ to <br />Shadywood) Yes <br />Minimum side yard setback: 10 feet Side 1: 7 feet Yes <br />Minimum rear yard setback: Lesser of 40’ or <br />20% of lot depth (30 feet) <br />Lesser of 40’ or <br />20% of lot depth No <br />Maximum FAR: 0.50 .43 (assumes 3,400 <br />sq ft single story <br />home) <br />No <br />Wetland building setback: Greater of 35 feet or <br />MCWD buffer plus 10 feet <br />35 feet (Lot 6) Yes <br />Private Recreational Area: 10% of gross project area 0% proposed Yes <br />Building height: Maximum of 30 feet (Not defined) No <br />All dwelling units, including manufactured homes, shall have a depth of at least 20 <br />feet for at least 50 percent of their width. All dwelling units, including manufactured <br />homes, shall have a width of at least 20 feet for at least 50 percent of their depth. <br /> <br />No <br /> <br />Updated information <br />Due to the nature of ongoing review of the application in addition to the Planning Commission’s <br />recommendations, the applicant has revised the drawings, provided as Exhibit A and summarized here: <br /> <br />Engineering Review: Review of the preliminary information was completed on July 21, 2016 and <br />forwarded to the applicant. In response, staff met with the applicant to go over these comments, many of <br />which were based on incomplete storm water planning; this information has been provided and is being <br />reviewed. Should the Council wish to approve the preliminary plat, staff suggests a condition that all <br />engineering comments be addressed to the satisfaction of staff and the city engineer. <br /> <br />It was noted during the planning commission review that the proposed ponds required the removal of <br />several significant trees. Responding to the goal of preserving as many trees as possible, the developer <br />proposes to use pervious pavers in the driveways and reconfiguring the pond shape and locations. Adding <br />pervious pavers reduces the hardcover as calculated by the watershed district below their review <br />threshold, meaning their rules pertaining to rate and volume do not apply. However, because of the <br />history of flooding in the area, in particular along Kelly Avenue, staff has evaluated the grading plan to <br />ensure that storm-water is retained onsite and distributed at the current (predevelopment) rate and volume
The URL can be used to link to this page
Your browser does not support the video tag.