� _ -- - --- .._ _ _ __ _------- ---. -__ ---- -- _ __--_.__. <br /> -- - ----_.._________----_.__ _ -. �_ <br /> j RHVAC-Residential,HVAC Load Calculations Elite Software Development,Inc. <br /> Flare Heating&A/C Inc. � Advanced Homes Orono Model <br /> Golden Vailey, MN 55427-3700 _ Pa e 2 <br /> -- --- -- ---_.�-. - <br /> -._ _______ __.._. _._...__---- - <br /> Total BuiJding Summary Loads � <br /> ___-- ------- _ ___ __ _ <br /> _- <br /> . _. _.. __----- -- _�..._...____..- -......___-- <br /> ' ; Component Area Sen Lat Sen Totai 1 <br /> i i Description __ _ _ _ _ __ Quan _ ___ Loss _ Gain Gain Gain � � <br /> �, 4A Window Double Pane& Storm Clear Glass Wood Frame 382 11,462 0 10,939 10,939 I <br /> i 8M Glass Door pouble Clear Glass Wood Frame 80 3,880 0 2,496 2,496 � <br /> ; 11C Door Metal Polystyrene Core 38 1,571 0 402 402 i <br /> 121 Wall R-19 + 1/2" Asphlt Board(R-1.3) 3201 15,493 0 4,684 4,684 j <br /> 13H Part R-19 + 1/2" GypsumBoard(R-0.5) 255 1,346 0 275 275 ; <br /> 15G Wall 5'or More Below Grade 8/12" BIk+R-11 880 3,329 0 0 0 'i <br /> 161 Ceiling R-44 Insulation 1693 3,427 0 1,830 1,830 ', <br /> � 20J Fioor Over Open Crawl Carpet + R-30 538 1,657 0 339 339 I <br /> � 21A Basemt Floor 2'or More Below Grade 1155 2,439 0 0 0 <br /> � Subtotals for structure: 44,604 0 20,965 20,965 '',; <br /> Peopie: 5 1,150 1,500 2,650 <br /> Equipment: 300 1,200 1,500 '- <br /> Lighting� 0 0 0 ', <br /> Ductwork: 0 0 0 d <br /> Infil#ration: Winter CFM: 244, Summer CFM: 122 22,944 3,423 2,998 6,421 ' <br /> � Ventilation: Winter CFM: 125, Summer CFM: 125 11,740 3,503 3,068 6,571 ' <br /> ; Sensible Gain Total: 29,731 <br /> '; Temperature Swing Multiplier: X 1.00 <br /> ', Total Building Load Totals: 79,288 8,376 29,731 38,107 ; <br /> ' ----� ----_---- <br /> -------------- <br /> , j Check Figures <br /> : ---_.__....--- --...__�_____. <br /> Total Building Suppiy CFM: 1,249 CFM Per Square ft.: 0.312 ' <br /> ! Square ft. of Room Area: 4,003 Square ft. Per Ton: 1,260.551 �� <br /> � <br /> Total'Heating Required With Outside Air:` 79,288 Btuh 79.288 MBH ` �' <br /> � <br /> Total Sensible Gain: 29,731 Btuh 78 % <br /> , Total Latent Gain: 8,376 Btuh 22 % <br /> i Total Cooling Required With Outside Air: 38,107 Btuh 3.176 Tons (Based On Sensible + Latent) <br /> 3.303 Tons{Based On 75°/o Sensible Capacity) <br /> ' ,---- - ------------ <br /> ' Notes - --- -------------- <br /> � --- -- --- __.,,__ _ <br /> �I <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> Ail computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. ' <br /> i <br /> i I <br /> i <br /> � <br /> ;� <br /> �I <br /> i <br /> i <br /> I <br /> i <br /> � <br /> I <br /> i <br /> i <br /> � <br /> i � <br /> i <br /> , <br /> S:\FHDATA\PROJECTSIJOSH1Advanced Homes Orono ModeLrhv VUednesday, January 29, 2014, 12:57 PM <br />