� ' • . . - . -.._ . __ _-...-- - ----- ___.--- -� - --- - --� �-� -� <br /> Go den Valele d MN a5542 g37 oommercial HVAC Loads � Elite Software Development,Inc. <br /> � ' � <br /> I Flare Heatin &A/C Inc. 2335 Glendale Cove,Orono � <br /> _ - y' _ _------- _ - - -- -- - - ------- Page 3'' <br /> ___ _ - - - -_ __ <br /> _ - __ _- _-- <br /> � Total Building Summary Loads <br /> _ _ _ _ _ - -- -- __- - -- - <br /> - - -- - -- - -- -- _-- -- - <br /> � Component Area Sen Lat Sen Total � <br /> Description Quan Loss Gain Gain Gain <br /> ---- - - --- - -----__-__- - -- - <br /> , 2A-v-o: Glazing-Double pane low-e (e =0.60), operable 734 22,607 0 17,133 17,133 � <br /> window, vinyl frame, outdoor insect screen with 50% <br /> � coverage, light color blinds at 45°with 50% <br /> coverage, u-value 0.35, SHGC 0.36 <br /> 11 N: Door-Metal - Polystyrene Core 38 1,170 0 426 426 �' <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 3779.5 21,618 0 5,232 5,232 j <br /> cavity, no board insulation, siding finish, wood studs <br /> 15B0-15sf-4: Wall-Basement, , R-15 board insulation to 264 1,162 0 130 130 I <br /> floor, no interior finish, 4'floor depth <br /> I 15B0-15sf-8: Wall-Basement, , R-15 board insulation to 704 2,603 0 0 0 ' <br /> floor, no interior finish, 8'floor depth <br /> ' 12F1-Osw: Wall-Frame, R-21 open ceil 1/2 Ib. sprayfoam 289.5 1,656 0 400 400 ' <br /> insulation in 2 x 6 stud cavity, no board insulation, ,, <br /> siding finish, wood studs <br /> 16B-44: Roof/Ceiling-Under Attic with Insulation on Attic 1765 3,417 0 2,174 2,174 j <br /> I Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark j <br /> I Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-44 insulation I <br /> 21 A-20: Floor-Basement, Concrete slab, any thickness, 2 1382 3,284 0 0 0 I <br /> , or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide <br /> i 20P-30: Floor-Over open crawl space or garage, Passive, 383 1,180 0 214 214 I <br /> R-30 blanket insulation, any cover � <br /> Subtotals for structure: 58,697 0 25,709 25,709 <br /> i People: 6 1,200 1,380 2,580 I <br /> Equipment: 683 3,430 4,113 <br /> Lighting: 0 0 0 I <br /> Ductwork: 4,262 301 1,053 1,354 I <br /> Infiltration: Winter CFM: 458, Summer CFM: 414 43,050 5,987 9,280 15,267 <br /> Ventilation: Winter CFM: 83, Summer CFM: 83 1,637 1,200 391 1,591 j <br /> ' Exhaust: Winter CFM: 480, Summer CFM: 480 <br /> I AED Excursion: 0 0 4,478 4,478 i <br /> Total Building Load Totals: 107,646 9,371 45,721 55,091 <br /> - - -- - <br /> ' Check Figures -- __-__ - - � <br /> Total Building Supply CFM: 2,124 CFM Per Square ft.: 0.469 <br /> Square ft. of Room Area: 4,529 Square ft. Per Ton: 987 j <br /> ' Volume (ft3)of Cond. Space: 43,142 <br /> - --- - _ - - <br /> _ _----- ---- - <br /> ! Building Loads l <br /> ----- --- - ---- ------ <br /> Total Heating Required Including Ventilation Air: 107,646 Btuh 107.646 MBH � <br /> Total Sensible Gain: 45,721 Btuh 83 % I <br /> Total Latent Gain: 9,371 Btuh 17 % <br /> ' Total Cooling Required Including Ventilation Air: 55,091 Btuh 4.59 Tons (Based On Sensible + Latent) <br /> , Notes ---- -- -- -- -_- - - - _� I <br /> � Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> , Calculations are performed per ACCA Manual J Sth Edition, Version 2, and ACCA Manual D. ! <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. , <br /> I <br /> \\flaresbs\company ...�Advanced Hom ... d, Orono.rh9 Monday, July 27, 2015, 7:54 AM <br />