Laserfiche WebLink
�5 � 4 <br /> . �} ����' � ���� ��i� <br /> . -, �; �� r ,� <br /> r �, <br /> . � • " � . f,.%�#_+" �. <br /> �'�` Pernut Number <br /> MECcheck Compliance Report <br /> 1999 Minnesota Energy Code <br /> MECcheck Software Version 32 Release 1 Checked By/Date <br /> TITLE: 204304 <br /> COiJNTY:Hennepin <br /> STATE:Minnesota <br /> ZONE: 2 <br /> CONSTRUCTION T'YPE: Single Family <br /> DATE: 06/O 1/04 <br /> DAT'E OF PLANS: 5/27/04 <br /> PROJECT INFORMATION: <br /> ORONO MODEL <br /> 1220 GARDEN COURT <br /> ORONO,NIN <br /> COMPANY INFORMATION: <br /> R.V.C. HOMES INC. <br /> COMPLIANCE:Passes <br /> Maximum UA= 792 <br /> Your Home=583 <br /> 26.4%Better Than Code <br /> Gross Glazing <br /> Area or Cavity Cont. or poor <br /> Perimeter R-Value R-Value U-Factor UA <br /> Ceiling 1:Raised or Energy Truss 16'74 44.0 0.0 37 <br /> Wall l: Wood Frame, 16"o.c. 4989 19.0 0.0 253 <br /> Window 1: <br /> Above Grade, Vinyl Frame,Double Pane with Low-E 576 0.320 184 <br /> Door 1: Solid 50 0.140 7 <br /> Door 2: Glass 82 0.320 26 <br /> Basement Wall i: <br /> Solid Concrete or Masonry, 9.0'ht/8.5'bg/9.0'insul 801 11.0 0.0 44 <br /> Basement Wa112: <br /> Solid Concrete or Masonry, 9.0'ht/4.5'bg/9.0'insul 351 11.0 0.0 26 <br /> Floor 1: All-Wood Joist/Truss,Over Outside Air 173 30.0 0.0 6 <br /> Furnace 1: Forced Hot Air, 90 AFUE <br /> Proposed and Mazimum U-Factor Averages <br /> Proposed MaYimum <br /> Average U-Factor Allowed U-Factor <br /> Above-Grade Windows and Giass Doors 0320 0.370 <br /> Includes Foundation Windows>5.6 ft2 <br />