My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00813 - septic
Orono
>
Property Files
>
Street Address
>
F
>
French Lake Road
>
2195 French Lake Road - 10-117-23-21-0006
>
Septic
>
2009-00813 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:20:28 PM
Creation date
12/8/2016 12:41:22 PM
Metadata
Fields
Template:
x Address Old
House Number
2195
Street Name
French Lake
Street Type
Road
Address
2195 French Lake Road
Document Type
Septic
PIN
1011723210006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
unvEum oe urnanor� <br /> �..J1",_ <br /> MinnesotaPollution Design Flow and Soil Worksheet . _ . =_ ., ��� ` ; <br /> �, <br /> Control Agency `y"��� <br /> 1. AVERAGE DESIGN FLOW: <br /> Note: The estimated design flow is considered a peak <br /> A. Estimated Design Ftow(GPD): 750 �� flow rate including a safety factor. For long term <br /> performance,the average daily flow is recommended <br /> or Measured Flow(GPD):flow times safety factor to be<60%of this value. <br /> � 4Pd X � _ ���Pd <br /> Design F(ow: 75� Gallons Per Day(GPD) System Type <br /> B. Septic Tank capacity: �Galtons ❑� TYPe I ❑TVPe n ❑rype ut ❑rvpe iv ❑rype v <br /> Number of Septic Tanks or Compnrtments: � Effluent Screen&Alarm? Yes <br /> Table 1- Design Flow(Gallons Per Day) Table 11-Septic Tdnk Capdcity <br /> Number of Classification of Dwelling Number of Septic Tank Liquid N�trimum Capacity with Garbage Disposal and/or <br /> Bedrooms I 11 III Iv g��ms Capacities(Gallons} Sewage Pum to Tanf� <br /> 2 or less 300 225 �80 ' 3 or less 1,000 1,50d <br /> 3 450 300 218 ' <br /> 4 600 375 256 • 4 or 5 1,500 2,250 <br /> 5 750 450 294 ' 6 a 7 Z>000 3,000 <br /> 6 900 525 332 ` 8 Or9 2,500 3,750 <br /> 'Flows for Classification IV dwellings are 60 percent of the values as determined for Classification I, II or 111 systems. <br /> 2. SRE EVALUATION: <br /> Texture Group <br /> A. Depih to Limi[ing Layer: 24 inches 2•� ft <br /> Soil Tmcture Group M <br /> Type of Soii Treatrnent and Dispersal Area Coarse Sand 1 <br /> B. Medtum Sand 2 <br /> �Trendies �Bed �At-Grade �Mound Fine Sand 3 <br /> Coarse Loamy Sand 4 <br /> Medium Loamy Sand 4 <br /> Type of Di�n"bution Fine Loamy Sand 5 <br /> C. Very Flne Laamy Sand 5 <br /> �Gravity Distribudon �Pressure DistributiorrLevel �Preswre Distribudon-Unlevel Coarse Sandy Loam 6 <br /> Medtum Sandy Loam 6 <br /> Fine Sarxly Loam 7 <br /> Very Fine Sandy Loam 7 <br /> D. Landscape Position: � Back/ Side Slope ��m $ <br /> Silt Loam 9 <br /> Clay Loam 10 <br /> E. Estimated Percent Land Slope: 12-U :� Sitty Clay Loam �o <br /> Sandy Clay Loam 10 <br /> or Rise Run suq uay �� <br /> s�,dy ctay �i <br /> F. Calculc►ted Slope = � .- � x 100= � ctay » <br />
The URL can be used to link to this page
Your browser does not support the video tag.