Laserfiche WebLink
- <br /> � Compliance Inspection �orm for Existing <br /> �.� <br /> Individual Sewage Treatment Systems <br /> v- <br /> This form reflects the requirements of the 1996 version of MN Rules Chapter 7080 <br /> Minnesota Pollution Control Agency <br /> Note:Local inspection standards may be more or less restrictive than the state requirements. These differences must be made available by the Local <br /> Unit of Government. <br /> Date of Inspection: <br /> Property Owner(s) - Telephone( ) <br /> Person requesting inspection(if different than owner) Telephone( ) <br /> Reason for inspection: •. % <br /> Site Address ��.�, �� �. � . City � f�. �; <br /> Zip Code Unit of Government Regulating this property ; ' ~ �./ <br /> Fire No. Parcel No. Township Name T <br /> Township Range Section Quarter <br /> (Check appropriate sewer system component and indicate location on site sketch). <br /> Tank s : Soil Treatment s,sy tem: Other(briefly deseribe): Flow Meter <br /> �_- Septic tank . Rock trench _Altemative system <br /> Aerobic tank y Gravelless pipe trench _Experimental system Yes , No <br /> Pump tank Chamber trench Warrantied system If yes, <br /> L Holding tank Seepage bed Exp.Date: <br /> Other Mound Other <br /> _At-grade <br /> �stem Classification <br /> System Built Prior to April 1, 1996 and not Located in Any System located in Shoreland or Wellhead <br /> Shoreland or Wellhead Protection Area or Serving a Protection Area or Serving a Food, Beverage ar <br /> Food, Beverage or Lodging Establishment Lodging Establishment, plus all systems Built after <br /> April 1, 1996 <br /> Is the system an imminent public health threat(IPHT)?Upgrade Is the system an IPAT? U�grade <br /> 1.Discharge of sewage to the ground surface? YES NO 10 mo 1.Discharge of sewage to the ground surface? YES NO 10 mo <br /> 2.Discharge of sewage to draintile 2.Discharge of sewage to draintile or <br /> or surface waters? YES NO 10 mo surface waters? YES I�O 10 mo <br /> 3.Sewage backup into dwelling? YES NO 10 mo 3.Sewage backup into dwelling? YES 'NO 10 mo <br /> 4. Situation with the potential to immediately and 4.Situation with the potential immediately and <br /> adversely impact or threaten public health or adverseiy impact or threaten public health or <br /> safety? YES NO 10 mo safety? YES {'f�IO 10 mo <br /> Is the svstem failing? Is the system failing? " ' <br /> 5.Less than TWO feet of vertical separation between 5.Less than THREE feet of vertical separation betweg��. <br /> system bottom and saturated soil or bedrock? YES NO LGU** system bottom and saturated soil or bedrock? �YES „J�3£3 �,GU** <br /> 6.A seepage pit,cesspool,drywell,or leaching pit? YES NO LGU** 6.A seepage pit, cesspool,drywell,or leaching pit?YE3 NO LGU** <br /> ** LGU=Local Unit of Government ordinance must specify the time period within which the system must be upgraded. <br /> STATUS OF THE SYSTEM <br /> Based on the compliance criteria above the system status is (check ope)C] in compliance(functioning)[]failing O an imminent threat <br /> therefore,this document is a(check one)�Certificate of Compliance .�)Notice of Noncompliance. <br /> E <br /> Page 1 of 2 <br />