Laserfiche WebLink
' EMSL Order: 351608314 <br /> EMSL Analytical, Inc. Customer ID: BRAU50 <br /> 14375 23rd Avenue North Minneapolis,Mn 55447 Customer PO: <br /> Phone/Fax:(763)449-4922/(763)449-4924 Project ID: <br /> M h�tp��www.EMSLcom/minneapolislab@emsLcom <br /> Attention: Derek Schilling Phone: (952)995-2674 <br /> Braun Intertec Fax: (952)995-2020 <br /> 11001 Hampshire Avenue South Received: 11/29/2016 12:30 PM <br /> Bloomington, MN 55438 Analysis Date: 11/30/2016 <br /> Collected: 11/29/2016 <br /> Project: 3907 CHERRYAVE/61611189 <br /> Test Report: Asbestos Analysis of Bulk Materials by PLM via EPA 600/R-93/116 Method <br /> using Polarized Light Microscopy. Quantitation using 400 Point Count Procedure <br /> Non-Asbestos Asbestos <br /> Sample Description Appearance %Fibrous %Non-Fibrous °/.Type <br /> 16A MAIN FLOOR NORTH Brown/Tan 9925%Non-fibrous(Other) 0.75%Actinolite <br /> 351608314-0018 ENTRYWAY SOUTH Non-Fibrous <br /> WALL,VERMICULITE <br /> INSULATION Homogeneous <br /> 16B MAIN FLOOR NORTH BrownlTan 100°/Non-fibrous(Other) <0.25%aActinolite <br /> 351608314-0o1s ENTRYWAY SOUTH Non-Fibrous <br /> WALL,VERMICULITE <br /> INSULATION Homogeneous <br /> 16C MAIN FLOOR NORTH Brown/Tan 100%Non-fibrous(Other) <0.25�oActinolite <br /> 351608314-0020 ENTRYWAY SOUTH Non-Fibrous <br /> WALL,VERMICULITE <br /> INSULATION Homogeneous <br /> Anatyst(s) �-- `'�` <br /> Nicholas Asuncion(3) Rachel Travis,Laboratory Manager <br /> or other approved signatory <br /> Disclaimer:Some samples may contain asbestos fibers present in dimensions below PLM resolution limits.The limit of detection as stated in the method is 025%. EMSL Analytical Inc suggests that <br /> samples reported as<0.25%or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced,except in full,without <br /> written approval of EMSL Analytical Inc.This test report must not be used by the client to daim produd endorsement by NVLAP or any agency of the United States Govemment. EMSL Matytical Inc., <br /> bears no responsibility for sample co�lection activitles,analytical method limitations,or the accuracy of resutts when requested to separate layered samples. EMSL Analytical Inc.,Iiability is limited to <br /> the cost of sample analysis.The test resul[s wntained within this report meet the requirements of NELAC unless otherwise noled.Samples received in good condition unless otherwise noted.Unless <br /> requested by the client,building materials manufactured with multiple layers(i.e.lindeum,wallboard,etc.)are reported as a single sample. <br /> Samples analyzed by EMSLAnalylical,Inc.Minneapdis,Mn <br /> Initial report from:11/30I2016 14:54:50 <br /> Printed 11/30/2016 1:54:51PM Page 1 of 1 <br />