Table II. Bulk Asbestos Analytical Results <br /> 3907 Cherry Avenue,Mound,MN 55364 <br /> B1611189 <br /> Page 2 <br /> Sample No. Sample Location Material Asbestos Content(%) <br /> 14 Main Floor Living Room South Wa�l Sheetrock/joint compound N.D. <br /> 15 Second Floor West Bedroom At Ceiling Blown-in insulation(brown)with N.D. <br /> tarpaper layers(black) <br /> 16A Main Floor North Entryway South Wall Vermiculite insulation(small grain)- Actinolite 0.75` <br /> ceiling&wall cavities <br /> Vermiculite insulation(small grain)- <br /> 16B Main Floor North Entryway South Wall Actinolite <0.25 <br /> ceiling&wall cavities <br /> Vermiculite insulation(small grain)- <br /> 16C Main Floor North Entryway South Wall Actinolite <0.25 <br /> ceiling&wail cavities <br /> 17 Exterior East Side At Chimney Brick&mortar N.D. <br /> 18 Roof Second Floor Outside NW Shingles(red,multi-colored,&green N.D. <br /> Window layers) <br /> 19 Exterior East Side In Electrical Box Braided electrical wiring N.D. <br /> ' Materials containing 1 percent of asbestos or less are not considered to be asbestos-containing materials by the U.S.EPA. <br /> 1. Asbestos content is indicated as an approximate percent by area. <br /> 2. N.D.=None Detected <br /> 3. N.A.=Not Analyzed <br /> 4. Vermiculite insulation was observed in the ceiling and wall cavities. The samples collected of the vermiculite insulation indicated trace amounts <br /> (less than 1%actinolite)of asbestos content.The EPA,MPCA,and the MDH consider any building material found to contain 1 percent or less asbestos <br /> to be a"non-asbestos containing material."However,due to the"scientific uncertainties associated with existing testing techniques"the EPA and <br /> MPCA recommend assuming that all vermiculite insulation contains asbestos.This is a developing issue with the regulatory agencies and it is our <br /> recommendation to request a specific interpretation for the site. <br /> gRauN <br /> INTERTEC <br />