My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01513 demo
Orono
>
Property Files
>
Street Address
>
C
>
Cherry Avenue
>
3907 Cherry Avenue - 08-117-23-33-0027
>
Permits/Inspections
>
2016-01513 demo
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:44:44 PM
Creation date
12/8/2016 9:47:21 AM
Metadata
Fields
Template:
x Address Old
House Number
3907
Street Name
Cherry
Street Type
Avenue
Address
3907 Cherry Ave
Document Type
Permits/Inspections
PIN
0811723330027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pride Construction <br /> Project 61611189 <br /> November 30, 2016 <br /> Page 4 <br /> C.3.a. Mercury <br /> ■ Electrical Systems—electrical paneis, load meters,supply relays,control switches. <br /> ■ Heating—natural gas furnace <br /> ■ Lighting—fiuorescent lamps <br /> C.3.b. Miscellaneous <br /> Gas Meter <br /> Water Heater <br /> D. Discussion <br /> D.1. Asbestos-Containing Materials <br /> D.1.a. Friable ACM <br /> The following asbestos-containing materials are classified as friable materials according to EPA 40 CFR <br /> Part 61 National Emission Standard for Hazardous Air Poltutants (NESHAPs): <br /> ■ 1-3" millboard pipe insulation with tarpaper layers <br /> ■ Vermiculite insulation (small grain) -ceiling&wall cavities—See Below <br /> ■ Vibration dampener gasket(white, cloth) <br /> Note: Vermiculite insulation was observed in the ceiling and wall cavities. The samples collected of the <br /> vermiculite insulation indicated trace amounts(less than 1%actinolite)of asbestos content.The EPA, <br /> MPCA,and the MDH consider any building material found to contain 1 percent or less asbestos to be a <br /> "non-asbestos containing material." However, due to the "scientific uncertainties associated with <br /> existing testing techniques"the EPA and MPCA recommend assuming that all vermiculite insulation <br /> contains asbestos.This is a developing issue with the regulatory agencies and it is our recommendation <br /> to request a specific interpretation for the site. <br /> The above friable ACMs were observed to be in good condition at the time of our assessment.These <br /> materials should be maintained in good condition to prevent potential exposure to asbestos. Friable <br /> ACMs are to be removed prior to disturbance by demolition in accordance with applicable state and <br /> federal regulations. <br /> eRAUN <br /> INTERTEC <br />
The URL can be used to link to this page
Your browser does not support the video tag.