Laserfiche WebLink
/� O—� <br /> // � � <br /> � <br /> ii O O ' <br /> � CITY of ORONO <br /> ,, <br /> � r ;'`� a� ' <br /> �� ,; ,�a!' �_��. t�v!�� Muni ' <br /> I �',, ��� Z�� .,!.. , ,� cipal Offices <br /> � �.� f:��':�" Street Address `�5a-a�}q'y 60 � Mailing Address: <br /> `qkEgg04' ' 2750 Kefley Parkway P.O. Box 66 <br /> - _ " Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: f 3�O �r t^�� C{c�c�C �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> YSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM" An LSTS which meets aIl the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or rivo foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public healU7 or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than thrce feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Taril:inspection indicates: <br /> CPumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 1l+-�C-CZ ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic sVstem to prolonE life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workin�in vour house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> taril:s have not been pumped out within the last three years,they should be pumped out now. <br /> RAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> coMMErrTs: (9�-�,:��-.-tl,� � 0��5 GK- _ �U�-� S�� �.-� ��� �,�.�cS <br /> `s,;��t� Z��c� _ <br /> �—�b-o � � �'�� ��� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantce or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />