Laserfiche WebLink
;i�O_\� <br /> � \ �\ <br /> i/ <br /> �' �� <br /> !/O O <br /> � � CI�Y of ORONO <br /> ,� � � r ��'��° � � � <br /> „� '� y ',!: �. ti Municipal Offices <br /> � � � ���` G�" � Street Address �15a.-a'�q-�"�60 0 <br /> Mailing Address: <br /> t��ESH�¢� 2750 Kelley Parkway P.O. Boz 66 <br /> -- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: � ���� r� t��� ���`K 'J�-- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITI' (1-3): I <br /> Ol "CODE SYSTEM" An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inunuient threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): J� <br /> Tanl:inspection indicates: <br /> UPumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped � '�'c; '� ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper <br /> cieanin�. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workinQ in your house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> �Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: r'`o�^c� � Ob��S �� � ����.� S�g �-L }�,�.kj 5���� <br /> �.0 1� - —� <br /> � _��_�� �-,� � <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> no[ guazantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />