My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00650-septic - (not sure if all papers go with this permit)
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1270 French Creek Drive - 10-117-23-32-0014
>
Septic
>
2015-00650-septic - (not sure if all papers go with this permit)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:52 PM
Creation date
12/5/2016 2:26:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1270
Street Name
French Creek
Street Type
Drive
Address
1270 French Creek Drive
Document Type
Septic
PIN
1011723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MinnesotaPollution OSTP Design Summary Worksheet UNIVERSITY '' ,;�rt; _` <br /> Cont1rol Agen�y OF MINNESOTA �,�1.y <br /> Mound Design Summary <br /> Absorption Bed Area�ft2 Bed Length�ft Bed Width�ft <br /> Absorption Width�ft Ctean Sand Lift�ft Berm Width (0-1%)�ft <br /> Upslope Berm Width�ft Downslope Berm Width �ft Endslope Berm Width�ft <br /> TotalSystem Length�ft TotalSystem Width�ft Contour Loading Rate C�gal/ft <br /> At-Grade Oesign Summary <br /> Absorption Bed Width�ft Absorption Bed Length�ft System Height��ft <br /> Contour Loading Rate�gal/ft Upslope Berm Width�ft Downslope Berm Width�ft <br /> Endslope Berm Width�ft System Length�ft System Width�ft <br /> Levei 8 Equal Pressure Distribution Summary <br /> No. of Perforated Laterals 8 Perforation Spacing 3 ft Perforation Diameter 7/32 in <br /> Lateral Diameter 2.00 in Min. Delivered Volume 168 gal Maximum Delivered Volu 188 gal <br /> Non-Level and Unequal Pressure Distribution Summary <br /> Elevation Pipe Volume Pipe Length Perforation Size <br /> (ft) Pipe Size(in) (gal/ft) (ft) (in) Spacing(ft) Spacing(in) <br /> Laterat 1 Minimum Delivered Volume <br /> Lateral 2 ��al <br /> Lateral 3 <br /> Lateral 4 Maximum Delivered Volume <br /> Lateral 5 �gal <br /> Lateral 6 <br /> 5, Additional Info for Type IV/Pretreatment Design <br /> A. Ca(culate the organic loading <br /> t. Organic Loading to Pretreatment Unit =Design Flow X Estimated BOD in mg/L in the effluent X 8.35=1,000,000 <br /> gpd X �mg/L X 8.35:1,000>000= �lbs BOD/day <br /> 2. Type of Pretreatment Unit Being Installed: <br /> 3. Calculate Soi( Treatment System Orgonic Looding: BOD concentrotion after pretreatment=Bottom Area =lbs/day/ftZ <br /> mg/L X 8.35: 1,000,000 : �ftz= �lbs/day/ftZ <br /> Comments/Special Design Considerations: <br /> I hereby certify that I have completed this work in accordance with all applicable ordinances, rules and laws. <br /> Swedlund Septic 2502 3/13/15 <br /> (Designer) ( ignature) (License#) (Date) <br />
The URL can be used to link to this page
Your browser does not support the video tag.