My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00650-septic - (not sure if all papers go with this permit)
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1270 French Creek Drive - 10-117-23-32-0014
>
Septic
>
2015-00650-septic - (not sure if all papers go with this permit)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:52 PM
Creation date
12/5/2016 2:26:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1270
Street Name
French Creek
Street Type
Drive
Address
1270 French Creek Drive
Document Type
Septic
PIN
1011723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, -.;=; <br /> '�e,��� r,�... <br /> �N I VERS I`I'Y Septic System Management Plan <br /> r OF�MINNESOTA .for Below Grade Systems -� <br /> � <br /> _����`�v <br /> Professional Management Tasks <br /> These are the operation and maintenance activities that a pumper/maintainer performs to help ensure <br /> long-term perfo�-mance of your system. Professionals should refer to the O/M Manual for detailed <br /> checklists for tanks,pumps, alarms and other components. Call 800-322-8642 for more details. <br /> • Written record provided to homeowner after each visit. <br /> Plumbing/Source of Wastewater <br /> • Review the Water Use Appliance Chart on Page 5 with homeowner. Discuss any changes in <br /> water use and the impact those changes may have on the septic system. <br /> • Review water usage rates (if available)with homeowner. <br /> Septic Tank/Pump Tanks <br /> • Manhole lid. A riser is recommended if the lid is not accessible from the ground surface. Insulate <br /> the riser cover for frost protection. <br /> • Liguid level. Check to make sure the tank is not leaking. The liquid level should be level with the <br /> bottom of the outlet pipe. (If the water level is below the bottom of the outlet pipe, the tank may <br /> not be watertight. If the water level is higber than the bottom of the outlet pipe of the tank, the <br /> effluent screen may need cleaning, or there may be ponding in the drainfield.) <br /> • Inspection pipes. Replace damaged caps. <br /> • Baffles. Check to make sure they are in place and attached, and that inlet/outlet baffles are clear <br /> of buildup or obstructions. <br /> • Effluent screen. Check to make sure it is in place; clean per manufacturer recommendation. <br /> Recominend retrofitted installation if one is not present. <br /> • Alarm. Verify that the alarm warks. <br /> • Scum and sludge. Measure scum and sludge in each compartment of each septic and pump tank, <br /> pump if needed. <br /> Pump <br /> • Pump and controls. Check to make sure the pump and controls are operating correctly. <br /> • Pump vault. Check to make sure it is in place; clean per manufacturer recommendations. <br /> • Alarm. Verify that the alarm works. <br /> • Drai�iback. Check to make sure it is operating properly. <br /> • Event counter or run time. Check to see if there is an event counter or run time log far the pump. <br /> If there is one, calculate the water usage rate and compare to the anticipated average daily flow <br /> listed on Page 2. <br /> Soil Treatment Area <br /> • Inspection pipes. Check to make sure they are properly capped. Replace caps that are damaged. <br /> • Surfacing of effluent. Check for surfaced effluent or other signs of problems. <br /> • Gravity trenches and beds. Check the number of gravity trenches with ponded effluent. Identify <br /> the percentage of the system in use. Determine if action is needed. <br /> • Pressure trenches and beds -Lateral flushing. Check lateral distribution; if cleanouts exist, flush <br /> and clean as needed. <br /> All other components—inspect as listed here: <br /> - 4 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.