. � <br /> City of Orono Septic System Apr_�val <br /> ISTS DESIGN �y��.� <br /> YES NO NA <br /> ISTS design specifications shall include proposed flows or other sizing information, minimum sewage tank <br /> capacity, minimum soil treatment area requirements,a plan of the component layout and all other information <br /> necessary to assure the City that the ISTS is designed and will be constructed to receive,treat and dispose of a�l <br /> of the sewa e from the buildin served. <br /> Setbacks <br /> Feature Sewa e Tank feet Soil Treatment Area feet <br /> Dee well 50 50 <br /> Wetland 50 50 <br /> General Develo ment Lake 75 75 <br /> Recreational Develo ment Lake 75 75 <br /> Natural Environment Lake 150 150 <br /> Tributaries/Streams 75 75 <br /> / Drivewa s, sidewalks,decks and other hardcover 10 10 <br /> / Pro e lines, buildin s and buried i es 10 20 <br /> Lawn s rinkler s stems 10 10 <br /> Sewa e Tanks. <br /> Number of Bedrooms Tanks Liquid Capacities( allons <br /> 4 or less 1,000+ 1,000 re ardless of arba e dis osal use <br /> 5 or 6 1,250+ 1,000 re ardless of arba e dis osal use <br /> 7,8 or 9 1,500+ 1,500 re ardless of arba e dis osal use <br /> 10 or more Sewa e tanks shall be sized as other establishments er MN Rules 7080. <br /> Pum in Stations. <br /> � In order to standardize installation and electrical connection methods,the following pumping station requirements <br /> must be met in addition to MN Rules cha ter 7080 <br /> Electrical connectio�: <br /> A waterti ht,lockable electrical box must be mounted on a four-inch b four-inch treated redwood or cedar ost. <br /> � All electrical connections shall be made within the box. Pump connection must not be made using a direct line <br /> lu -in onl . Wire ent to the electrical box shall be sealed with a waterti ht material such as foam or u . <br /> Alarm and um floats shall be on se arate electrical circuits. <br /> Eleetrical wire from the power supply must not run over any tanks and must be laid beside the tanks and placed in <br /> conduit alon the electrical ost. <br /> Electrical cords from the pump and floats must be run through a two-inch PVC(or equivalent)conduit(schedule <br /> 80)with a one-inch gap between the conduit and the electrical box. Electrical cords must not run through or under <br /> the manhole cover. Wires must not have round contact. <br /> Pum in Chamber: <br /> Pressure pipe exiting the pumping chamber must be laid on a uniform slope up to the soil treatment area for <br /> proper drain back. The pressure pipe must be sleeved and inside a larger diameter pipe for additional support if <br /> spanning ground that has been excavated. If the pipe at the tank must be lower than union to get elevation for <br /> drain back,a one- uarter inch wee hole must be used. <br /> � When soil depths above the pressure distribution pipe is less than 3'/2 feet, insulation must be added to achieve <br /> an insulating factor equal to 3'/2 feet of soil to decrease the potential for freezing(Styrofoam or concentric piping <br /> are acceptable methods). Piping under hardcover,such as tennis courts or driveways shall be insulated pipe or <br /> e uivalent. <br /> A reserve capacity equaling 75% of the anticipated daily flow must be allowed into the pumping chamber between <br /> the alarm activation level and the um tank inlet. <br /> Protection of drainfield area. <br /> Proposed drainfield areas shall be identified and marked off on the lot at the time of the site evaluation and prior to <br /> any construction or grading occurring in the area. The drainfield area shall remain undisturbed until drainfield <br /> construction is commenced. No vehicular traffic shall be allowed in the drainfield area either before or after <br /> ainfield installation. <br /> ACCEPTED DENIED by the Metro West on behalf of the City of Orono subject to existing regulations and the <br /> following conditions: <br /> Inspections r quired: �`/) �'y� �I <br /> 1. � • ✓ N w u.... �.�.w�lC ��� A i�-e�a.l �� d� <br /> 2. t�' �r t se • i <br /> 3. C•,.�,l - .... .c a/ � .,... <br /> i•.s, s ..,.,a- as 6�• < � .. ...., <br /> gy Printed Name: �C,�OlpC�1.7 /C p h ��lu� Date: <br /> G ����.,j�� <br /> w:\se ic\septic system approval revised 2-2015.docx <br /> Page 2 of 2 <br />