2015-00650-septic - (not sure if all papers go with this permit)
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1270 French Creek Drive - 10-117-23-32-0014
>
Septic
>
2015-00650-septic - (not sure if all papers go with this permit)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:52 PM
Creation date
12/5/2016 2:26:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1270
Street Name
French Creek
Street Type
Drive
Address
1270 French Creek Drive
Document Type
Septic
PIN
1011723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . <br /> INSPECTOR CHECKLIST -Mu[ti fiow - Pressure bed <br /> 1270 French Creek Dr.,Orono <br /> � WELL secbacks: 2Q'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersai area with shatlow wetl <br /> PROPERTY L(NES sc�back: 10'to everything <br /> Road se�track: outer ditch,or 33'from center of township road,or 65'from center of cnty road <br /> LAKE/BLUFF setback: 20'for btuff. Lakes:GD_,RD_,NE_. Protected wettand <br /> Building secbacks: 1d for everything, 20'for dfspersat area. <br /> WATER LINti under pressure se 70'to bed,tank Fx sewer line. (else sewer line>12"betow) <br /> � Sewer tine&baffle connection {no 90's, 3'between 45's,stope min i"in 8',max 2"in 8'), <br /> (no depth req's, ctean out every 100', Sch 4d D2665 or F891) <br /> � Sepcic tank and risers twater tight,insulated,proper depth,existing verified by pumping) <br /> mfg 1000 gallans trash trap/multi-flow dose tank <br /> Riser over outtet, riser over inlet, 6"+inspection pipe over any remaining baffles. <br /> 750 gallon Multi•ftow unit UV iight req d No <br /> Treatrttent pump 30 gpm 10 head 17.6 gal 35 sec ON 29.q min OFF <br /> ' 12 ft 2 inch supply tine <br /> � timer ON ftbat 18 inches from bottom HlA at 75%tank capacity <br /> Dispersai: <br /> � Dose tank risers and piping (water tight,tnsulated,proper depth,drainback) <br /> mfct 1000 ga[lons <br /> � dose pump 46 gpm 15 head VERfFY PUMP CURVE 4.2 min ON 9 hr OFF <br /> � ftoat setting drop 19.1 inches 191 gat dose <br /> LABEL pump requirements and drawdow�on riser or panel <br /> � Cam tock, weep hote, suppty line access (no hard 90,pipes reachable from grade-30"� <br /> � supply pipe sloped 1/8"+, supported by sch40 steeve, and buried 6"+. <br /> � sptice box/co�trol pane(/electricat connections <br /> Bed dimensions 18 X 54.0 <br /> Rock depth below pipe 12 inches <br /> Rock bottom elevation 18.0 inches from Grade to bottom of rock(max) <br /> � cover depth of 12"+ VERIFY <br /> 6 taterals (t-2'irom ed�e of rock) <br /> 1.50 inch pipe size <br /> 3.0 ft lateral spacing <br /> � 3/1b inch perforations (smalter is ok) <br /> � 3.0 ft perforation spacing <br /> Air intet at end of laterats, and at top feed manifold. VERIFY <br /> clean outs (deep bed 2'of head) (no hard 90's) <br /> 4"inspection pipe to bottom of rock,anchored VERIFY <br /> Abandon existing system if necessary �Re-use existing tank certification <br /> monitoring ptan and type <br /> welt abandonment if necessary <br /> i <br /> I <br /> I <br /> � <br /> � <br /> I <br /> i <br /> i <br />