My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00650-septic - (not sure if all papers go with this permit)
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1270 French Creek Drive - 10-117-23-32-0014
>
Septic
>
2015-00650-septic - (not sure if all papers go with this permit)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:25:52 PM
Creation date
12/5/2016 2:26:48 PM
Metadata
Fields
Template:
x Address Old
House Number
1270
Street Name
French Creek
Street Type
Drive
Address
1270 French Creek Drive
Document Type
Septic
PIN
1011723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011purplecode Multi Flow �t Pressure Bed <br /> www.SepticResource.com (vers 12.6) <br /> Property Owner: Andrea Mueller Date: 5/6/2014 <br /> Site Address: 1270 French Creek Dr.,Orono p�p; <br /> Comments: <br /> instr�ctions: [�=site specific input �=adjust if desired �=setf-calculated(DO NOT ADJUST) <br /> n �bedroom Type IV Restdential System <br /> �) 750 GPD design ftow <br /> PRETREATMENT: (Residential strength to ievel A/B) <br /> s� 10pfl Galton Trash trap/pump tank to Mutti-flow 2 existing 1 trash trap-t dosing tank <br /> a� 750 Gallon Mutti-flow unit UV light req d No <br /> 30 gpm 10 ft head TREATMENT pump 48 doses per day 15.6 gat/dose(treatment) <br /> s� 12 feet of 2.0 inch supply(ine leads to 2 galions of drainback volume <br /> 17.6 gallons toYal pump out votume <br /> Timed dosing of 35 sec QN {confirm pump rate with drawdown <br /> 29.4 min OFF test and adjust as necessary} <br /> 18 inches from bottom of tank to Timer ON float <br /> e� Hi level Alarm to be set at 75 %of tank capacity <br /> DISPERSAL: <br /> �� 0•78 GPD/ft� Soit Loading Rate 972 ft2{code minimum) 972 ft2(design size/LUG req'd) <br /> Treatment Levei A/B (must match soil boring tog) <br /> s� 18.0 ft desired bed width, leads to a 54,0 ft bed tength <br /> {25'maximum) <br /> 9) 3.0 ft lateral spacing 3.D ft perforation spacing (maximum 3 for both} <br /> end feed manifold connection <br /> 3�� ��laterats 52.� fee[long 18.0 perfs I lateral 108 perfs totat <br /> (1/2 perf ineans the 1st perf starts at the middle feed manifold) <br /> �U 3/16 inch perfs at �i feet residua(head gives 0.42 gpm ftow rate per perfora[ion <br /> (If bed has> 1'of cover,increase residual head for deanout req's) <br /> for this perf size&spacing,£t pipe size on line 14,max perfs/laterat= 22 ,Gne 1i10 must be less--� OK <br /> iz> 4.0 doses per day {4 minimum) <br /> r� 188 gattons per dose (treatment votume) <br /> �a} 1.50 inch diameter laterats(or smatler)will meet"Sx pipe votume <br /> 1,50 inch diameter laterals(or smaller)must be used to meet"4x pipe votume"requirement <br /> 2.00 inch diameter latera{s{or smaller)witl meet"3x pipe votume" <br /> � - ---__�_ ---- <br /> � <br /> � <br /> i <br /> ' <br /> i <br />