Laserfiche WebLink
�,�� <br /> --,,,� <br /> / � �\``. <br /> � �� � <br /> ��� �� � �I�Y of ORONO <br /> ,� , t ,,� �., <br /> � � ��, 1, , �ti Municipal Offices <br /> �'C� , , :'. .� �. <br /> Street Address: �lSa-a4q-�"I6� O Mailing Address: <br /> ��`9� ���`�� p�'����� 2750 Kelley Parkway P.O. Box 66 <br /> ESH <br /> --- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> ToCurrentOwner: Address: ��6� �"�c^c�` �Ct� �j�, <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y 1-3 : � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and conshvction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inuninent threat to public heald�or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipa]Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �� <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped i\—y��3 )• <br /> Make sure septic tanks are pumped through manhole and not throuQh white inspection pipes. This allows for the proper <br /> cleaninQ. Keep water softner and iron filter discharge out of septic system to prolon�life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : d <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: ��-��-V � 5���� L �-���LS �a0� U�� <br /> � �� _4� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />