I TYPICAL MACHINE SPACE LAYOUT TYPICAL MACHINE SPACE LAYOUT I, _ _ WORK BY OTHERS (5 of 6) I <br /> _ _ _- - - - - - - -_ __ . <br /> _ _ - - _ <br /> -- - - - - - - - - - - --- - _ <br /> � (PLAN VIEW-Remote Machine Room) (ELEVATION VIEW) � _c_oNrw►croR <br /> I ; Minimum 6'8"overhead/headroom required above controller in the machine space. <br /> I Contractor provide access to machine space for hydraulic piping and electrical wiring.Contractor to ciose up after I <br /> i Fea.a�orowe e�a��e a2,.c r«aram. I i <br /> �:,�.r��e�ac z.�Ha„a�e�.. elevator installadon.Access to machine space field located by Arrow-Lift. <br /> iz3w wq sr�ana� � i. <br /> �e�,�,;a�ambem cr�a�c �e , Contractor rovide ro r backin ? " ) g q p <br /> �nn,�.r ��z.a H�,ae�.. P P Pe 9(bP• z Plywood or O56 for mountln of elevator controller&e�ectncal e ui ment. <br /> � �,,,,�,p,a; ,,,„,,,,,y�, usv�sn,� rn�x � � , Contrador to provide fire retardant paint on rail wall plywood with label on plywood for retardant coating. I <br /> hySauk GP5 rtl detlrinl wiiy<.�atlor ro Ek<tr[bn 0�'Ee maUiM TEkWKKIE ScvK!f0r Ekvd[IX�\�. � . I <br /> tbu W aRv ekva - �n. ���'�M"��^9�O a°"� . I <br /> �w�� �e.��o•� '""'"oar°nitlwcspaG il , �p—y�r °1 Elevator controller can be built into wall framing. <br /> -' - °� 1 � 9 P) <br /> II _ �W��iKe i � c ControllePr Size: 30"wide x 22"hi h x 8'�d��uipment or a urtenances not related to the elevator. I <br /> ;� Machine s ace shall be clean and clear of an pp <br /> � �� s '��� r��n�zo� _ � � -� /� i <br /> ��� ! ��W�R 36��� ' ���°�/ T Fire Separation per Authority Having Junsdiction(AHJ)and Local Building Codes. <br /> E o„g �I ��de�e w�wad�7 '�� <br /> �� �_e? I ���, ,�,� na«co�o-aw o��/ <br /> � E E y o�' "., . (Fu4bk aM Lodade) '. <br /> I ��a � i ELECTRIQAN <br /> -- I ��___ _�� MAIN CONTROL BOR ' <br /> - Electrician provide dedicated circuit for elevator main powec 230V,30A Sin4e Phase.Feeder breaker must not be <br /> ii -r '�- � <br /> _. . � �-. �-, <br /> ���^+��E � T „,�,,,,.0 � � ,� GFi.Tertnina[e at handibox at designated locatlon,4"above control box and 4"from latch side of control box to center <br /> �.N �. ww�o�a�o. �a�mm j � = --- -� ' <br /> �g g of box.Cap Feeds and cover Box. <br /> - ,� i _. :-. : <br /> - <br /> � ,! _ - - _: _ : _ - __ � g 22 I Electrician provide dedicated circuit for elevator cab lighting.115V,15A,Single Phase.Feeder breaker must not be <br /> I �aa�a,„w, a � GFI.Tertninate at handibox a[designated location,2"above control box and 4"from latch side of control box to center of I <br /> ' E'�tla "�"°a0a0 °�^o°�"^°°�y�r°� � box.Ca Feeds and cover Box. <br /> ',�nw�s s�c� mwM�a n�xa c�aaie.. �I � I�, p I <br /> I �,,;�;,,�„d;�„�, j j r-� �� c Electrician provide dedicated circuit for machine space light and outlet.115V,15A,Single Phase I <br /> � ��e� ` - I <br /> �sy,�s�s�� II € - -�- - _ l� i <br /> �, �,oade�;,�,� � �- - - - - -� Eiectrician provide Live Phone Line to machine space in conduit.Terminate conduit at 2x4 Handibox at designated I <br /> I �����a�° SwYA aM CiCi r f . <br /> � �,,,,,, �a�����N I I location,2"above control box and 10"from latch side of control box to center of conduit Cap Feeds and cover Box. j <br /> ITermnate rt Oay�atM bation. mu4 Ge iN�atlml al tlnatrw�ruiK. ' - I I <br /> I i �ZZ 1�4 —� Electrician provide Light Switch and GFCI Outlet in machine space.Typically 2 gang Switch and GFCI recep[ade I <br /> i � � i located on latch side of machine space door.OuUet and Switch must be independent of elevator circuits. � <br /> m Hroanuuc ' Electrician provide overhead lighting in machine space.Switched overhead lighdng to provide 19 ftc at floor of machine j <br /> NOTE: Remote machine space,contractor � POWER UNIT i space. i <br /> � fTIUSt BIIOw f0�hydrdUliC piping frOm hyd�dUliC i Any equipment below elevator controller must protrude less than 6"from che face of the serviceable box. i <br /> ' pump to hoistway rail walL , � <br /> j I Proper Electrical Flashback clearances must be maintained per NEC: <br /> � 36"D x 30"W required flashback in front of eleva[or controller. ��R,�,� � <br /> ' � Notes on Controller Location:Power must be"hot"with breakers . MOif1SOri R0S1dCT1CC__ � <br /> I I�� ,'�J � shut and taped off prior to installaGoo.Cap MC and flex at terminatlon �°"'E 8 �5 2�1$ MdChin2 SpdcE i <br /> i pointr(final elevator conVoller mounting locatlon).Arrow-LiR to � � SpeCifiCations_� <br /> provide wiring from termination point to elevator.Elevaror controller odnvm ev Pnce - <br /> __ __ i shall be located to meet NEC Flashback and working clearances. �.V. 8 Of 9 <br /> ! MAIN CONTROL BOX ., I � � � - � � - <br /> I i 30"H x 22"W x�8"D <br /> NOTE:Typical Machine Space Layouts may not be � <br /> yyareuiic Power unit indicative of exact site conditions.Drawin s used �� ���� <br /> Typiwl Machine Space Layoutr I 33 1�z"H x 22 lq"W x 12 3q"D 9 : <br /> may not be indicative of exad _ __ f0�IIIUSCrdtlVe PU�pO5e5 OIIIy. <br /> �ske conditions.Drawings used �� <br /> ���;���Stra��e P����o��Y. Eleuating EXcellence <br />