Laserfiche WebLink
'---�. <br /> ,�� �\� <br /> � <br /> �� � ''� <br /> ;�' ���� ������ CITY of �RONO <br /> �� � ,:� , � ,,,-��:�� �. <br /> ,�r�,,� �? ,g, � � �� � Municipal Offices <br /> .t9 "¢,� Street Address `•15a.-a'�{9�y6o O Mailing Address: <br /> �ESH� 2750 Kelley Parkway P.O. Boz 66 <br /> -_� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ���`� ��t^c\ ��CzK U��_ <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTBM CONFORMIT`Y 1-� : � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requuement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an unminent threat[o public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or conshuction stan�rds of the current Orono Municipal Code and which is faIling for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �—1�—C3 ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic sVstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workin�in your house. The alarm warns owner that septaee is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: Q` �.-^�-.-���I ;}— S�Q ��:�-- �,�5 I b�I� 6I� � <br /> -7 -\� '�� G� G�� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to sa[isfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />