My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01099 - pressure bed septic system
Orono
>
Property Files
>
Street Address
>
F
>
French Creek Drive
>
1205 French Creek Drive - 10-117-23-23-0001
>
Septic
>
2015-01099 - pressure bed septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:21:02 PM
Creation date
12/1/2016 12:48:16 PM
Metadata
Fields
Template:
x Address Old
House Number
1205
Street Name
French Creek
Street Type
Drive
Address
1205 French Creek Drive
Document Type
Septic
PIN
1011723230001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SP TFSTiNG INC. <br /> Steven B.Schirrners -951 Katydid Lane NE-St. Michael,MN 55376 <br /> Cert.No 627 - State License#394 - Phone 763-497-3566 - Fax 763-497-5011 <br /> www.sqtestin�.wastewater comcast net- schirmerswastewater.com <br /> July 28, 2015 <br /> Clark 8 Sharon Winslow <br /> 1205 French Creek Dr. <br /> Orono, MN <br /> This onsite sewage treatment system is designed for a Type 1 system corrected <br /> (original soil below the system with 1.2' of sand) Type 1, 6 bedroom home in <br /> accordance with the Minnesota Poiiution Controf Agency chapter 7080 & locai <br /> ordinances. <br /> The existing tanks may be used. <br /> The soils on this site are a sandy loom to loamy sand. The system wil! need to be <br /> removed, lowest trench at elev. 85.1 & .3' below the system (possible pugged soils <br /> elev.94.8) 8 then backfitl with washed sand to elev. 86.0 using SB#2 with mott[ed <br /> soil at elev. 93.0 which will meet a 3' separation. A pressurized seepage bed with be <br /> instalied with 12"of rock, 1-1/2" distribution pipe, 3/16" perforations 36" apart. <br /> Cover with 2"of rock 8 a minimum 8� 6" of loam topsoil. <br /> The existing trenches owtsjde of the seepage bed must be roughened up a minimum <br /> of 3'from the edge of the seepage bed. <br /> The west line is approxirnate 1� must be located prfor to installation. The property <br /> line shown is from an old aerial photo. <br /> This site has very limited space for access for repairing the systen� 8 may require <br /> access from a neighboring property to ins#all the system. <br /> The existing pumping chamber will Ilft the effluent to the treatment area. The power <br /> supply � switches must be located outside the manhole 8 pumping chamber in a <br /> weather proof enclosure. A warning device must be installed with a light 8 sound <br /> device, this is in case of a purnp failure. <br />
The URL can be used to link to this page
Your browser does not support the video tag.