My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00899 - detached garage
Orono
>
Property Files
>
Street Address
>
F
>
Fairview Cottage Lane
>
1565 Fairview Cottage Lane - 07-117-23-43-0033
>
Permits/Inspections
>
2016-00899 - detached garage
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:39:42 PM
Creation date
12/1/2016 10:51:15 AM
Metadata
Fields
Template:
x Address Old
House Number
1565
Street Name
Fairview Cottage
Street Type
Lane
Address
1565 Fairview Cottage La
Document Type
Permits/Inspections
PIN
0711723430033
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
New Construction Energy Code Compliance Certificate <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside'1®ate Certificate Posted <br /> building. The certificate shall be completed by the builder and shall list information and values of components RIDS <br /> listed in Table N1101.8. 8/5/16 <br /> Mailing Address of the Dwelling or Dwelling Unit Minnetrista,MN <br /> Becker Residence Detached Garage ARCHITECTS <br /> Name of Residential Contractor MN License Number <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply Passive(No Fan) <br /> ,,- <br /> o N <br /> R tIN 0 COPYo <br /> T Active(With fan and manometer or <br /> > other system monitoring device) <br /> — ° ao :: <br /> Td ' T <br /> O vi y 2 2 G 'R O G. X y <br /> Insulation Location rx .9 o O w -- <br /> c N o 20 2 a o '' ti v <br /> l-- 5 z is. h. w w cG e4 Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X Exterior <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) X <br /> Rim Joist(l"Floor+) R-21 X Interior J <br /> Wall R-21 X <br /> Ceiling,flat R-50 X <br /> Ceiling,vaulted R-38 X <br /> Bay Windows or cantilevered areas <br /> Bonus room over garage R-38 X <br /> Describe other insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door )U: 0.32 X Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.29 R-value <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural Gas Natural Gas Electric Passive <br /> Manufacturer DAI KI N DAI KI N Powered <br /> Interlocked with exhaust device. <br /> Model DC96HS060 DX13018 Describe: <br /> Input in Capacity in Output in Other,describe: <br /> Rating or Size BTUS: 60,000 Gallons: Tons: 18,000 <br /> Heat Loss: Heat Gain: Location of duct or system: <br /> Structure's Calculated 38,785 4041100. 11,552 <br /> 90% SEER: 13 <br /> 96D/0 Calculated <br /> Efficiency cooling load: Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Type Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 35 High: 70 X Other,describe: Direct vent <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: - - <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: "metal duct <br /> Created by BAM version 052009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.