Laserfiche WebLink
/= �\ <br /> � <br /> ��� 7 � ��,. <br /> ii� �� � <br /> ���� � , �I�Y of �RONO <br /> ; <br /> :' p�j + � r��' .-_ �l <br /> �9 I � <br /> r�,, �;� '� , � !� �� Municipal Offices <br /> ti �; <br /> ���� � �`� ���� Street Address �153�-a49-ybo O Mailing Address: <br /> � ��� t ,' ��� �,� ',� .r <br /> `9�CEggOg'- 2750 Kelley Parkway P.O. Box 66 <br /> - -- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �a�� ��{^C� (�c�,�C C;r�I C <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3): � <br /> �1 CODE SYSTEM" An ISTS which meets all the]ocation,design and construction standards of the current Orono Municipal Code. <br /> "COMPLIANT SYSTEM" An LSTS which does not meet all the]ocation,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an unminent threat to public health or safety. <br /> 3 "NON-COMPLIf3NT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> T nk inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 1 l—�U-0; ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleanin�. Keep water softner and iron filter discharge out of septic sVstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workin�in your house. The alarm warns owner that septaQe is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tanl:. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> �INFIELD CONDITION(8-10): b <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> coMMENTs: ����:� �-:�1�1 �- stp�i� ��.r.k� Ioo�� a�, <br /> � -�'� -b� � �"�`� ��� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />