Laserfiche WebLink
#13-3591 <br /> 11 February 2013 <br /> Page 4 of 7 <br /> easements are proposed on the eastern half of the property as well as a portion <br /> across the southern lot line of the property to protect and preserve the existing <br /> tree stand. All required RR-1B setbacks can reasonably be met when this lot is <br /> � developed with a new home. The septic treatment sites are located out of the <br /> tree preservation area. . . <br /> Proposed Lot3: Lot 3 is proposed to have 110±feet in width at the cul-de-sac, and ±220 feet in <br /> width at the principal building setback, contains 2.63± dry acres in area. It <br /> appears all required RR-16 setbacks can reasonably be met when this lot is <br /> developed with a new home. Tree preservation easements are shown along the <br /> southern and western property boundaries. <br /> Proposed Lot4 Lot 4 is proposed to primarily front along the private road with a small portion <br /> accessing off the cul-de-sac. It is proposed to have 2.038± dry acres; it will have <br /> 298±feet of frontage on the new private road. The storm water pond makes up <br /> . approximately 0.15 acre of this lot. All required RR-1B setbacks can reasonably <br /> be met when this lot is redeveloped with a new home. This lot will also have a <br /> tree preservation easement along the western, rear lot line. <br /> Proposed CotS Lot 5 is proposed to contain 2.12 dry, buildable acres and 1,958 square feet of <br /> storm water pond. A tree preservation easement is proposed over the western <br /> and northern portions of the property. _ <br /> Road Layout and Standards . <br /> The applicant is proposing to plat Outlot A to create a private road with a cul-de-sac. An access permit is <br /> required from Hennepin County in order to relocate the access and create the private road. The <br /> Subdivision Ordinance and the CMP require a 50-foot corridor and a 100 foot cul-de-sac for a local <br /> private road. Street design information was submitted with the application materials and has been <br /> reviewed by City Engineer. The proposed paved width of the private road is shown as 20 feet where the <br /> Code requires 24 feet for 3 to 6 homes. A variance from the minimum paved width requirement would <br /> be necessary. The cul-de-sac is proposed to be 120' feet in diameter with a 24-foot paved width; a 47- <br /> foot landscaped center is proposed. <br /> Due to the location of the existing outlots connecting Outlot C to Bayside Road, the applicant's road <br /> design is proposed with a 100 foot curve radius which exceeds the City's minimum curve radius of 275 <br /> feet. The grade of the road in this area is approximately a ±13%slope;the recommended grade should <br /> not to exceed 12% (City Code 82-281 (e)]. The angle of the access and the steepness of this part of the <br /> property create an unfavorable and potentially unsafe situation for the roadway. The applicant has <br /> provided an exhibit to illustrate how the City's curve requirements impact the site layout. The Planning <br /> Commission should consider driving on Cristofori Circle before Tuesday's meeting; Cristofori Circle has a <br /> radius that is approximately 125 feet and the slope is around 10%. Keeping in mind, Cristofori Circle is <br /> not as extreme as what is being proposed but it has a similar slope and curve radius to get a real life feel <br /> for the road that is being proposed. Staff recommends the applicant redesign the road and lot lay out to <br /> better address the City Engineer's concerns regarding the road design. <br /> The applicant proposes to post the road "no parking" on the east side and install signage regarding the <br /> steep curve of the road. James Van Eyll our Fire Marshal has reviewed the plans had the following <br /> comment: According to Appendix D of the 2007 Minnesota State Fire Code, regarding Fire Apparatus <br />