2012-00980 in ground pool
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
3350 Fox Street - 05-117-23-44-0008
>
Permits/Inspections
>
2012-00980 in ground pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:22:36 PM
Creation date
11/29/2016 2:14:01 PM
Metadata
Fields
Template:
x Address Old
House Number
3350
Street Name
Fox
Street Type
Street
Address
3350 Fox St
Document Type
Permits/Inspections
PIN
0511723440008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 09 13 11 : 06a p. 5 <br /> , i <br /> Test#2— Pool Base (At Deep Section Centerline) <br /> DCP Depth Per Blow Avg. / N-Va�ue Estimated Load <br /> 659 MM (25.9") 36.3 MM/ N—8.5 3125 PSF <br /> Test#3—Pool West End (Flat Zone) <br /> DCP Depth I'er Blow Avq. 1 N-Value Estimated Load <br /> 1000 MM (39.4") 69,2 MM / N —4.3 1458 PSF <br /> IVote: Although test#1 indicates generally acceptable capacity, it only represents the composite <br /> average of soil below 2 feet within the area tested. It should be noted that the first hammer drop or <br /> set blow, penetrated over 560 MM, or 22" of soil. This upper layer of very soft su►face soil may <br /> settle as construction loads are applieci. It is therefore recommended that the area represented by <br /> Test#1, be corrected to increase consolidation and load-bearing capacity of the soils. <br /> As recommended, the contractor completed the soil correction, and the soils were retested on <br /> May 7, 2013 as follows: <br /> Test#4—Soif Correction Zone Test (Reference Test#1) <br /> DCP Depth Per Blow Avq. / N-Va1ue Estimafed Load <br /> 894 MM (35.2") 53.2 MM/ N — 5.75 1917 PSF <br /> In our opinion, with the noted soil correction, the observed and tested sub-grade soils are <br /> acceptab{e, and would be expected to meet a target bearing capacity of 1200/13d0 PSF, for the <br /> proposed construction. Our observations and subsequent soil evaluation for the project is limited in <br /> scope to soil conditions observed within the pool excavation, and to the depths achieved by shallow <br /> probes and dynamic cone penetrometer tests. Therefore, we are unable to assess sub-grade soils <br /> at an elevation, which may be encountered by borings conducted as part of a standard subsurface <br /> geotechnical investigation. <br /> Sincerely, <br /> Itco Alfied Engineering Company Reviewed By: <br /> � z,�?�� ���G��y��'�ed� <br /> Gary Standish Gordon J. Kopacek, P.E. <br /> Senior{nspector Minnesota Reg. #7254 <br /> CC: City of Orono Suilding lnspections <br /> #701 - 1 / #605— 1 1/2 I#610—'/4 I#304/ (4) DCP/ #612—60 1/2 <br />