Laserfiche WebLink
. •. . <br /> ----------- - - ---- - - -- --- --- - ------ - - - ---------- - --- --, <br /> ---- -- --- --- --- - ---- ------------------------------ � <br /> ' Rhvac-Residential 8�Light Commercial HVAC Loads � Elite Software Development,Inc� ', <br /> I'� West Metro Mechanical Inc. Kindl Residence <br /> �i� Norwood MN 5b368 _ ____ _ _ __ ____ Paae 6 ' <br /> � �- -� rY - - -- - ---- - - - --- ---- - - - - , <br /> ' 'i TotalBuildin Summa Loads <br /> - ' � <br /> � Component Area Sen Lat Sen Total ; ' <br /> �', Description _Quan_ Loss Gain ___Gain Gain ' , <br /> ��, 1 F-hw-o: Glazing-Triple pane, operable window, heat- 706 25,159 0 20,884 20,884 ', <br /> I absorbing, wood frame, u-value 0.44, SHGC 0.3 ', <br /> '�, 11A: Door-Wood- Hollow Core 240.5 9,157 0 3,052 3,052 �� <br /> I 1560-10sf-4: Wall-Basement, , R-10 board insulation to 1241.4 7,025 0 699 699 ' <br /> ��, floor, no interior finish, 4'floor depth �, <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2889.5 15,214 0 3,062 3,062 '�, <br /> cavity, no board insulation, siding finish, wood studs <br /> '�, 166-50: Roof/Ceiling-Under Attic with Insulation on Attic 2157 3,494 0 2,200 2,200 ' <br /> I Floor(also use for Knee Walls and Partition <br /> ��, Ceilings), Vented Attic, No Radiant Barrier, Dark ', <br /> ' Asphalt Shingles or Dark Metal, Tar and Gravel or I <br /> � Membrane, R-50 insulation ; <br /> I 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1611 3,524 0 0 0 II <br /> I or more feet below grade, no insulation below floor, �', <br /> � any floor cover, shortest side of floor slab is 20'wide I <br /> ' 20P-30: Floor-Over open crawl space or garage, Passive, 297 842 0 114 114 '' <br /> ! ___R-30_bl_anket ins_u_lation�any cover________________ <br /> Subtotals for structure: 64,415 0 30,011 30,011 <br /> , People: 0 0 0 0 <br /> '�, Equipment: 0 0 0 <br /> I Lighting: 0 0 0 <br /> I, Ductwork: 0 0 0 0 <br /> I Infiltration: WinterCFM: 182, SummerCFM: 97 15,719 1,928 1,663 3,591 <br /> ��, Ventilation: Winter CFM: 250, Summer CFM: 250 8,645 4,947 1,708 6,655 <br /> I Exhaust: Winter CFM: 250, Summer CFM: 250 <br /> I AED_Excursion:_ 0 0 126 126 <br /> �I Total Building Load Totals: 88,779 6,875 33,507 40,383 �I <br /> I Check Figures � i <br /> ; Total Building Supply CFM: 1,490 CFM Per Square ft.: 0.299 ' <br /> '�, Square ft. of Room Area: 4,976 Square ft. Per Ton: 1,479 , <br /> ', Volume (ft') of Cond. Space: 43,838 � <br /> �'I Building Loads � ; <br /> Total Heating Required Including Ventilation Air: 88,779 Btuh 88.779 MBH '� <br /> I Total Sensible Gain: 33,507 Btuh 83 % II <br /> I Total Latent Gain: 6,875 Btuh 17 % <br /> Total Cooling Required Including Ventilation Air: 40,383 Btuh 3.37 Tons (Based On Sensible + Latent) <br /> �, Notes <br /> I Rhvac is an ACCA approved Manual J and Manual D computer program. I <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> � All computed results are estimates as building use and weather may vary. <br /> 'I Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> �, your design conditions. <br /> '--- -------- ---- - - ---------- ------- ------ ' <br /> C:\...\Kindl Residence.rh9 Thursday, September 29, 2016, 12:18 PM <br />