My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01257 - building permit application/COO
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2649 Casco Point Road - 20-117-23-24-0029
>
Permits/Inspections
>
2016-01257 - building permit application/COO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:54:45 PM
Creation date
11/22/2016 11:53:31 AM
Metadata
Fields
Template:
x Address Old
House Number
2649
Street Name
Casco Point
Street Type
Road
Address
2649 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. 1 <br /> West Metro Mechanical Inc. � Kindl Residence I <br /> Norwood MN 55368 _ _ _ ___ _____-_--_ ___ _ Pa e 2 ' <br /> __ __ -- —_ __ - – <br /> �oject Report <br /> General Project Information <br /> Project Title: Kindl Residence <br /> Designed By: Andrew Franck � <br /> Project Date: Thursday, September 29, 2016 <br /> jI Desi n_Dat.a__ , <br /> � Reference City: Minneapolis/St. Paul AP, Minnesota �, <br /> Building Orientation: Front door faces North �, <br /> Daily Temperature Range: Medium <br /> � Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains , <br /> I � Bulb Wet Bulb Rel.Hupl Rel.Hum � Bulb Difference '� <br /> '� Winter: -11 -11.42 n/a n/a 70 n/a <br /> �� Summer: 88 71 44% 50% 72 30 ' <br /> Check Figures __ <br /> i Total Building Supply CFM: 1,490 CFM Per Square ft.: 0.299 <br /> Square ft. of Room Area: 4,976 Square ft. Per Ton: 1,479 <br /> � Volume (ft3) of Cond. Space: 43,838 <br /> I Building Loads <br /> I Total Heating Required Including Ventilation Air: 88,779 Btuh 88.779 MBH <br /> Total Sensible Gain: 33,507 Btuh 83 % <br /> Total Latent Gain: 6,875 Btuh 17 % <br /> Total Cooling Required Including Ventilation Air: 40,383 Btuh 3.37 Tons (Based On Sensible + Latent) <br /> — -_ _ — ---- <br /> ��� Notes � ��� <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. , <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> � <br /> C:\ ...\Kindl Residence.rh9 Thursday, September 29, 2016, 12:18 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.