My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01257 - building permit application/COO
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2649 Casco Point Road - 20-117-23-24-0029
>
Permits/Inspections
>
2016-01257 - building permit application/COO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:54:45 PM
Creation date
11/22/2016 11:53:31 AM
Metadata
Fields
Template:
x Address Old
House Number
2649
Street Name
Casco Point
Street Type
Road
Address
2649 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 1.This wall-bracing evaluation is based on the 2012 International Residential Code.The user is responsible for ensuring that the project fits within the <br /> scope of the IRC and complies with the wall-bracing requirements of Sections R602.10,R602.11 and R602.12 as applicable. <br /> 2.One-and two-family dwellings and townhouses in Seismic Design Categories A and B and one-and two-family dwellings in Seismic Design Category <br /> C are exempt from the seismic requirements of the IRC.The length of wall bracing shall be in accordance with the requirements of Table R602.10.3(1) <br /> based on wind speed,including all applicable adjustment factors. <br /> 3.Braced-wall lines using the continuous sheathing methods shall be constructed in accordance with the requirements of Sections R602.10.4.2, <br /> R602.10.6.4,and R602.10.7,as applicable. <br /> 4.Braced-wall panels shall be located at each end of braced-wall lines and may begin up to 10 feet from the end in accordance with Figure R602.10.2.2. <br /> Corner construction for continuously sheathed methods shall be in accordance with Section R602.10.7. <br /> 5.The distance between braced wall panels shall not exceed 20 feet in accordance with Section R602.10.2.2. <br /> 6.Braced-wall-line spacing shall not exceed 60 feet on center. <br /> 7.Interior braced-wall-line spacing is the greater of the distance between two adjacent braced-wall lines or the average of the distance as selected by the <br /> designer. <br /> 8.Refer to the Stronp-Wall Shearwalls�Prescintive Desian Guide(htt�://www.stronatie.com/literature/T-SWPDG.htmll for pre-engineered solutions when <br /> the required bracing amounts cannot be satisfied with prescriptive braced-wall panels.Simpson Strong-TieCR�Wood and Steel Strong-WaIIC�shearwalls <br /> may be considered equivalent to the code braced-wall panel construction method WSP with gypsum board applied on the inside. <br /> 9.Mixing of intermittent bracing methods within a braced-wall line is permitted only in Seismic Design Categories A and B and for detached dwellings in <br /> Seismic Design Category C.The length of bracing required for the braced-wall line shall be the highest bracing length calculated for each method used <br /> within the braced-wall line. <br /> 10. Horizontal panel joints in braced-wall panels shall be blocked in accordance with Section R602.10.10. <br /> 11. Braced-wall lines shall have a minimum of two braced wall panels unless the provisions of Section R602.10.2.3 are satisfied. <br /> Version 21.t <br />