2010-00299 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2880 Fox Street - 04-117-23-31-0011
>
Septic
>
2010-00299 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:11:08 PM
Creation date
11/14/2016 3:13:00 PM
Metadata
Fields
Template:
x Address Old
House Number
2880
Street Name
Fox
Street Type
Street
Address
2880 Fox St
Document Type
Septic
PIN
0411723310011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 4.. MOIJND SIZING <br /> A. Catculate Clean Sond Lift: 3 feet minus Depth to Limiting Condition (1.C) = C(eon Sond Lift (1 ft minimum) <br /> 3.0 ft - 1.3 ft = 1.7 ft <br /> B. Calculate Upslope Height: C(eon Sond Lift (4.A) +medio depth (1 ft.) + cover (1 ft.) = Upslope Height <br /> 1.7 ft + 1.0 ft + 1.0 ft= 3.7 ft <br /> D-34:Slope Multiplier Tabie <br /> Land$lope% 0 1 2 3 4 5 6 7 8 9 10 il I2 13 14 15 16 17 18 19 20 21 22 Z3 24 25 <br /> Upslope 3:1 3.00 2.y1 2.83 2.75 2.58 2.5t 2.SJ 2.�18 2.d2 2.36 2.31 2.25 2.21 2.t? 2.t3 2.G5 Z�5 Z.03 2.00 1.57 1.9i 7.93 1.9t I.89 1.E7 1.8i <br /> Bern�Ratio �:1 �i•00 3.85 3.70 3.57 3.�15 3.33 3.23 3.12 3.03 2.9�1 2.86 2.78 2.70 2.62 2.55 2.�{8 2.41 2.35 2.29 2.23 2.18 2.13 2.08 2.03 1.98 1.93 <br /> Land$lope m n 1 2 3 4 5 6 7 8 9 t0 11 12 i3 t4 15 16 i7 18 19 20 21 22 23 24 25 <br /> Cb�'tf1SI0PP ?:1 3.IX) 3.09 3.19 3.30 3.di 3.53 3.56 3.80 3.95 -l.11 J.29 1.d8 d.69 �.45 5,2a i.55 5.8$ 6.2J 6.63 7.W 7.d7 7.53 &.J2 8.4i 9..l6 SG.L2 <br /> Berm Ratio -l:1 d•00 �i•iT d35 d.51 J.76 S.CO 5.26 5.56 5.88 6.25 6.67 7.1J 7.65 8.29 8.92 9.57 10.2J 10.5J 11.67 12.d2 13.19 13.99 1.1.62 15.67 56.54 17.�11 <br /> Select Upslope Berm Multiplier <br /> �' (based on land slope): 2.36 (figure D-34) <br /> D. Calculate Upslope Berm Width: Multiplier (4.C)X Upslope Mound Heigf�t (4.B) = Upslope Berm Width <br /> 2.36 ft x 3.7 ft = 9.0 ft <br /> E. Calculate Drop in Elevation Under Bed: Bed Width (2.6) X Land Slope (1.D) : 100= Drop (ft) <br /> 10.0 ft x 9.00 % : �oo= 0.90 ft <br /> F. Calculate Downslope Mound Height: Upslope Height (4.B) +Drop in E(evation (4.E) =Downslope Height <br /> 3.7 ft + 0.90 ft = 4.6 ft <br /> Select Downslope Berm Multiplier <br /> G� (based on land slope): 4.11 (figure D-34) <br /> H. Calcutate Downs(ope Berm Width: Multip(ier (4.G) X Downs(ope Height (4.F) =Downslope Berm Width <br /> 4.11 x 4.6 ft = 19.0 ft <br /> I. Catculate Minimum Berm to Cover Absorption Area: Downs(ope Absorption Width (3.B or 3.C) +4 ft. =ft <br /> 14.0 ft + �4� ft = 18.0 ft <br /> J. Design Downslope Berm =greater of 4H and 41: 19.0 ft <br /> K. Select Endsiope Berm Multiplier: 3.00 (usualty 3.0 or 4.0) <br /> L. Calculate Endslope Berm (4.K) X Downs(ope Mound Height (4.F) =Endslope Berm Width <br /> 3.00 ft x 4.6 ft = 14.0 ft <br /> M. Calculate Mound Width: Ups(ope Berm Width(4.D) + Bed Width (2.B) + Downs(ope Berm Width (4.J) =ft <br /> 9.0 ft + 10.0 ft + 19.0 ft = 38.0 ft <br /> N. Calculate Mound Length: Ends(ope Berm Width (4.L) + Bed Length (2.C) + Endslope Berm Width (4.L) =ft <br /> 14.0 ft + 38.0 ft + 14.0 ft = 66.0 ft <br />