Laserfiche WebLink
/� O� <br /> ;�/� �\ <br /> �� % \ <br /> �'i � � ���'.�'� <br /> � CITY of URON� <br /> ; ,, . <br /> � �. <br /> , <br /> ��� , � , <br /> �, ,� �����-,.� <br /> , ,,, � <br /> �,, � x ; , � !��; Municipal Offices <br /> , , �; ti �: <br /> � ' ; ' ���' G Street Address: �153�-a�q—�"�6o O <br /> .� , �� .� ;; Mailing Address: <br /> ` ��ESHOg " 2750 Kelley Parkway P.O. Box 66 <br /> - -_- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��� ���� �� - <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet al][he location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an uruninent threat to public health or safety. <br /> ( 3 � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> ��� or may not meet all die location,design,or conswction stan�ards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �' <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> � Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �b`�-'�� ). <br /> Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This allows for the proper <br /> cleanin�. Keep water softner and iron filter dischar�e out of septic svstem to prolong life of drainfield Ask pumper to test <br /> alarm float to verifv alarm is still workinE in your house. The alarm warns owner that septage is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �Jc�ti,:��—_�`� �S ��r.t���_���G�.�t �-- n.�}.j— �: �'z,� 1c,cc� <br /> �'� \'L""l� �_"LCi� - \f +%^'�� S<�i'.L '�''�,�� Sv"^-�-Cr Z�L1,� .. <br /> �' C.��^U�"� " ' '`C� P�� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />