, <br /> � .; . <br /> Jesse Struve <br /> From: Jesse Struve <br /> Sent: Friday, April 18, 2014 2:48 PM <br /> To: Melanie Curtis <br /> Cc: Christine Mattson <br /> Subject: 20140418 2690 Fox St-#14-0298 <br /> Melanie, <br /> I reviewed the application for a proposed pool at 2690 Fox St and have the following comments: <br /> 1. The survey is not to scale. <br /> 2. Should the application also include hardcover calculations? <br /> 3. There is a retaining wall called out on the SW corner of the pool deck. Is this a proposed retaining wall or an <br /> existing wall? If it is being proposed,the top of wall (TW) and bottom of wall (BW) should be shown. Any wall <br /> over 4' in height and not separated by 2x the height of the upper wall (as measured from the face of the upper <br /> wall to the back of the lower wall), wili need to be designed by a registered professional engineer. If when I <br /> perform my as-built site review it does not meet the requirements,the applicant will be required to have an <br /> engineer sign off on the construction after-the-fact. <br /> 4. The survey should show the location of the silt fence. <br /> 5. Should the survey also show the alternate location of the septic system? <br /> Jesse Struve, PE <br /> Director of Public Works/City Engineer <br /> City of Orono <br /> (952) 249-4661 - Direct <br /> (952) 249-4616- Fax <br /> www.ci.orono.mn.us <br /> 1 <br />