My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic design-2015
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2660 Fox Street - 04-117-23-42-0001
>
Septic
>
septic design-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:13:34 PM
Creation date
11/10/2016 11:53:15 AM
Metadata
Fields
Template:
x Address Old
House Number
2660
Street Name
Fox
Street Type
Street
Address
2660 Fox St
Document Type
Septic
PIN
0411723420001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Minnesota Pollution , <br /> OSTP Desi�n Summary Worksheet UNIVERSITY <br /> ControlAgency OP MINI�'ESOTA '�,�`� �`` <br /> �' <br /> Mound Design Summary <br /> Absorption Area 625.0 ftz Bed Length 63.0 ft Bed Width 10.0 ft <br /> Absorption Width 72,p ft Clean Sand Lift �,5 ft Berm Width (0-1%)��ft <br /> Upslope Berm Width 10.0 ft Downslope Berm Width 24.7 ft Endslope Berm Width 13.5 ft <br /> To[atSystem Length g0.0 ft To[al5ystem Width 4q.7 ft Contour Loading Rate 12.0 gal/ft <br /> At-Grade Design Summary <br /> Absorption Bed Width��ft Absorption Bed Length��ft Sys[em Height�ft <br /> Contour Loading Rate��gal/ft Upstope Berm Width��ft Downslope Berm Width��ft <br /> Endslope Berm Width�ft System Length�{t System Width��ft <br /> Level&Equal Pressure Distribution Summary <br /> No.of Perforated Laterals�� Perforation Spacing�ft Perforation Diameter 7/32 in <br /> Lateral Diameter Z-� in Min. Delivered Volume��gal Maximum Delivered Volume 188 ga( <br /> Non-Levei and Unequal Pressure Distribution Summary <br /> Elevation Pipe Volume Pipe Length Perforation Size <br /> (ft) Pipe Size(in) (gaVft) (ft) (in) Spacing(ft) Spacing(in) <br /> Lateral 1 Minimum Delivered Votume <br /> Lateral 2 <br /> gal <br /> Lateral 3 <br /> Lateral 4 Maximum Delivered Volume <br /> Lateral 5 <br /> gal <br /> Lateral 6 <br /> 5. Additional Info for Type IV/Pretreatment Design <br /> A. Calculate the organic loading�sing option 1 or 1 <br /> 1. Organic Loading =Pounds of 80D X Units <br /> lbs/day X � _ �lbs BOD/day <br /> 2. Orqonic Loading to Pretreotment Unit =Design Flow X Estimated BOD in mg/L in the effluent X 8.35=1,000,000 <br /> gpd X � mg/L X 8.35=1,000,000= �tbs BOD/day <br /> B. Type of Pretreatment Unit Being Installed: <br /> C. Calculate Soil Treotment System Organic Loading: ibs. BOD/day:Bottom Areo =lbs/day/ftZ <br /> lbslday: �ftz= �lbs/day/ftZ <br /> Comments/Special Design Considerations: <br /> I hereby cer[ify that I have completed this work in accordanCe with alt appticable ordinances,rules and laws. <br /> :� <br /> Joseph J Olson - -�� � 810 04/12/14 <br /> (Designer) (Signature) (License#) (Date) <br />
The URL can be used to link to this page
Your browser does not support the video tag.