Laserfiche WebLink
�/��1 O�\� <br /> // 7 � <br /> � / O O\\`.1'� <br /> �� � �� CITY of ORONO <br /> � � �r t ��*i���,' l�y i I <br /> / L <br /> ���,�,, � z '��� � ,�ti�� Municipal Offices <br /> ,� �,, :��;� .-�,``� �' '% Street Address: �lSa-a4q-�16o 0 <br /> �� � � � � � <'y;'.� Mailing Address: <br /> � 9�ESHOg',-% 2750 Kelley Parkway P.O. Box 66 <br /> ---__= Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ���� ��X �fi- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): 6 <br /> _1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public healtli or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the luniting soil chazacteristics. <br /> TAI�'K CONDITION(5-7): � <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �^—��'b '� ). <br /> Make sure septic tanks are pumped throuQh manhole and not throueh white inspection pipes This allows for the proper <br /> cleanin�. Keep water softner and iron filter dischar�e out of septic svstem to prolon�life of drainfield Ask pumper to test <br /> alarm float to verifv alarm is still workin2 in vour house. The alarm warns owner that septage is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION 8-10 : �� <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: M o�Y� �0`Jk.� G'�_ , P""Q �tilf> �^�z� �vt r� <br /> '� Y ��fS <br /> � —�L`'�—o� ��c� � <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />