Laserfiche WebLink
� _ _ - - - _ _- - - --- - - - - _ _ _ _ - _ _ _ _ - - - - - <br /> � �RHVAC Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. <br /> Ditter, Inc JAFFERY <br /> I Hamel,MN 55340-9691 Page 2 <br /> I _ _ _ _ _ _ <br /> - -_- -__ . - ----_ . <br /> _---_ -_ _ - <br /> ' Total Building Summary Loads <br /> � Compo�nent Area Sen. Lat. Sen. Total I <br /> i Descn tion Quan Loss Gain Gain Gain � <br /> I 3A Window Double Pane Clear Glass Wood Frame 220 11,152 0 11,312 11,312 I <br /> 10F Door Wood Solid Core & Metal Storm 63 1,854 0 477 477 I, <br /> �I 12C Wall R-11 + 1/2 Gypsum(R-0.5) 1,621 13,422 0 3,443 3,443 I <br /> 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 896 6,594 0 1,690 1,690 � <br /> 16G Ceiling R-30 Insulation 768 2,332 0 1,115 1,115 ' <br /> 21A Basemt Floor 2' or More Below Grade 768 1,696 0 0 0 � <br /> . - _- - -- - <br /> _ _ - _ ____ _ - _ _ - _ _ - _ ___ -- - - - - - - - - - <br /> � Subtotals for structure: 4,336 37,050 0 18,037 18,037 <br /> � Active People: 6 0 1,380 1,800 3,180 i <br /> I Inactive People: 0 0 0 0 0 'I <br /> i, Appliances: 0 0 0 1,?_00 1,200 � <br /> Lighting: 0 0 0 ' <br /> Ductwork: 0 0 0 0 0 I <br /> � Infiltration: Winter CFM: 307.2, Summer CFM: 92.2 283 30,163 2,188 1,967 4,155 I <br /> i Ventilation: Winter CFM: 50.0, Summer CFM: 0.0 0 4,909 0 0 0 I <br /> - - -_ _ _- _ _- . _ __ _ - - <br /> I Sensible Gain Total: 23,004 � <br /> � Temperature Swing Multiplier: X1.00 <br /> Building Load Totals: 72,122 3,568 23,004 26,572 i <br /> _ _ _ - - - - -. --- -- - ___- - - - - _ <br /> ' Check Figures <br /> I Total Building Supply CFM: 1078 CFM per square foot: 1.403 � <br /> I Square feet of room area: 768 Square feet per ton: 300.469 � <br /> - - _ _ - __ . - - _ _ __ - --__---- <br /> _ _ _ _ . _ _ _ _ . <br /> Building Loads ! <br /> _ _ __ - - - -- -- - _ --- <br /> - - - - -- ___ _ -- - --- _- i <br /> � Total heating required with outside air: 72,122 Btuh 72.122 MBH I <br /> � Total sensible gain: 23,004 Btuh 87 % I <br /> � Total latent gain: 3,568 Btuh 13 % i <br /> 'I Total cooling required with outside air. 26,572 Btuh 2.214 Tons (based on sensible + latent) i <br /> i 2.556 Tons (based on 75% sensible capacity) I <br /> � ___ ___- - ----- - __ -----. _---- --_ __ __ - _- -___ - - _ _ _ __ I <br /> i Notes I <br /> _ _ - - -_ _ _ _ - ._ -- -- - - -----___ -- -- - <br /> I� Calculations are based on 7th edition of ACCA Manual J. I <br /> � All computed results are estimates as building use and weather may vary. I, <br /> I Be sure to select a unit that meets both sensible and latent loads. ! <br /> j I <br /> � <br /> i _ - - __ - _ _ _ _ --- --- - - _ _- __ __ _ - _ _ - �I <br /> Tuesday,June 27,2000 <br />