My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-00465 - septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2555 Fox Street - 04-117-23-44-0002
>
Septic
>
2012-00465 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:15:02 PM
Creation date
11/1/2016 12:10:52 PM
Metadata
Fields
Template:
x Address Old
House Number
2555
Street Name
Fox
Street Type
Street
Address
2555 Fox St
Document Type
Septic
PIN
0411723440002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, OSTP Pump Tank Sizin�, Dosing and Float <br /> UNIVERSITY ;�n '��� '"'�`"`° <br /> MinnesotaPollution and Timer Setting Design Worksheet � �s. � <br /> Cantrol Agency OF MINNESOTA =``.�•.,,� <br /> DETERMINE AREA AND/OR GALLONS PER INCH Project ID: v 11.09.22 <br /> 1. A. Rectangle area=Length(L)X Width(W) <br /> Width <br /> ��ft X �� ft = ��fiz <br /> B. Circle area=3.14�(3.14 X radius X radius) � � <br /> Length <br /> 3.14 X C�2 ft - ��fi2 <br /> �s <br /> C. Tank modet and manufacturer: CfeSt Radiu <br /> D. Get area from manufacturer ��ftZ <br /> E. Get gallons per inch from manufacturer 25.5 Gallons per inch <br /> 2. Calculate Gal(ons Per Inch: <br /> There are 7.48 gallons per cubic foot. Therefore,multiply the area from 1.A,1.B,or 1.0 by 7.48 to determine the gallons per faot <br /> the tank holds. Then divide that number by 12 to calculate the gallons per inch. <br /> (Area X 7.48 gattons/ft')/(12 in/ft)_ <br /> � ftZ X 7.48 gal/ft3 = 12 in/ft = 25.5 Gallons per inch <br /> TANK CAPACITY <br /> 3. Enter the Designed Pump Tank Copacity(minimum provided in the table): 1250 Gallons <br /> 4. Calculate Tota(Tonk Volume <br /> A. Depth from bottom of inlet pipe to tank bottom: 49.5 in <br /> B. Total Tank Vo(ume =Depth from bottom of inlet pipe (Line 4.A)X Gallons/Inch (Line 2) <br /> 49.5 in X 25.5 Gallons Per Inch = 1262.3 Gallons <br /> 5• Calcula[e Volume to Cover Pump (The inlet of the pump must be at least 4-inches from the bottom of <br /> the pump tank 8 2 inches of water covering the pump is recommended) <br /> � (Pump and btock height+2 inches)X Gallons Per Inch (1 D or 2) <br /> ( 15 in + 2 inches) X 25.5 Gallons Per Inch = 434 Gattons <br /> DOSING VOLUME <br /> 6. Minimum Pumpout Vo(ume -4 X Volume of Distribution Piping: 100.6 Galtons <br /> -Line 17 of the Pressure Distribution or Line 11 of Non-leve( <br /> 7. Calculate Maximum Pumpout Volume (25%of Design Flow) <br /> Design Flow: 750 GPD X 0.25 = 187,5 Gallons <br /> 8. Select a pumpout volume that meets both items above (Line 6&7): 188 Gallons <br /> 9. Calculate Doses Per Day =Design Flow=Dosing Volume <br /> �so gpd = 188 gat = 4.0 Doses Volume af Liquid in <br /> 10. Calculate Drainback: PiPe <br /> A. DiameterofSupplyPipe= C2�inches Plp2 Liquid <br /> -_J <br /> B. Leng[h of Supply Pipe= 140 feet Diameter Per Foot <br /> C. Vo(ume of Liquid Per Linea(Foot of Pipe = 0.170 Gallons/ft (i nches) �Cid��0115� <br /> D. Drainback =Length of Suppl y Pipe X Volume of Liquid Per Linea(Foot of Pipe � 0.045 <br /> 140 ft X 0.170 gal/ft = 23.8 Galtons 1.25 0.078 <br /> 11. Tota(Dosing Volume =Dosing Volume (Line 8)plus Drainback (Line 10.D) �.5 0.110 <br /> 188 ga� + 23.8 gal= 212 Gatlons 2 0.170 <br /> 12. Minimum Alarm Yolume=Depth of alarm(2 or 3 inches)X gallons per inch of tank(Line 1 or 2) 3 0.380 <br /> C�in X 25.50 gal/in = 76.5 �allons 4 0.661 <br /> `1`�' eF- �3� <br />
The URL can be used to link to this page
Your browser does not support the video tag.