My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-00110 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2650 Fox Street - 04-117-23-41-0003
>
Septic
>
2011-00110 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:13:14 PM
Creation date
10/21/2016 2:43:35 PM
Metadata
Fields
Template:
x Address Old
House Number
2650
Street Name
Fox
Street Type
Street
Address
2650 Fox St
Document Type
Septic
PIN
0411723410003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2500 gallon Septic tank (minimum) Multiple tanks or compartment req'd <br /> 1500 qallon Dose tank (minimum) at approximately 31.00 gpi <br /> 71 GPM C� 26 ft. of head, Pump required <br /> 5.3 inch swing on Demand float <br /> 17 inches from bottom of tank to "pump ON"float <br /> 20 inches from bottom of tank to "Hi Level Alarm"float <br /> 75 ft. of 2.0 inch supply line with end feed manifold connection <br /> 22 inch, or 1.83 ft. Sand Lift Mound <br /> 10 ft. wide by 62.5 ft. long Rock bed <br /> 3 laterals 1.25 inch diameter 60.5 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> YES Effluent fitter E� alarm <br /> 3 dean out�t valve box assemblies <br /> 27.0 ft.Total sand ABSORPTION width (minimum) <br /> 6.0 ft. upslope and sideslope (sand beyond rockbed) <br /> 17.0 ft. Downslope (sand beyond rockbed) <br /> BERM widths (topsoil beyond rockbed) using 4:1 slope ratio <br /> 10 ft. upslope berm <br /> 12 ft. sideslope berms <br /> 31 ft. downslope berm optional 21 ft. downslope C� 3:1 slope <br /> 4" inspection pipe <br /> 18" cover on top <br /> lJ sto e berm �� Downsto e berm 31 <br /> -12" cover on sides <br /> ..--``��� ��''�-,` (6"loamy cap&6°topsoii) <br /> 1.83 �::k�.�r� �<�nci lift -`'�-- <br /> -�..., <br /> __ 1.17 Deptt� to Limitino <br /> Limitir�� Condition� ' "___�,---________.____ <br /> Absar tion Width 27.0 ______._�._._. _._.___.�_ .--. - ,-_ -- -_ <br /> Note: <br /> For 0 to 1% slopes, Absorption Width is measured from the Bedequaily in both directions. <br /> For stopes >1�, Absorptlon �clth is measured downhitl from the upslope edge of the Bed. <br /> Rock Bed: 21 yd'or'1.4= 34 ton <br /> Mound Sand: 259 yd3 or`1.4= 363 ton <br /> Loamy Cap: 87 yd3 or*1.4= 122 ton • <br /> Topsoil: 99 yd3 or'1.4= 139 ton <br />
The URL can be used to link to this page
Your browser does not support the video tag.