Laserfiche WebLink
0 <br /> o � NOTES: � <br /> � ` 1. MAIN LEVEL FLOOR SHEATHING TO BE 3/4"PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131 QJ x 3"LONG NAILS <br /> � <br /> �' �a 6"O.C.AT PANEL EDGES&@ 12"O.C.AT PANEL INTERIOR SUPPORTS. <br /> � � 2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT. PLACE NAILS AT LEAST 3"FROM EACH OTHER <br /> � &1y" FROM BLOCKING EDGES. INSTALL LARGER OR ADDITIONAL BLOCKING MEMBERS AS NEEDED TO MEET THESE <br /> � REQUIREMENTS OR FIT NON-STANDARD FLOOR MEMBER SIZES&SPACES. <br /> m � � �v (� (� z -r1 N 3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE BLOCKING, DESIGNED FOR 1500 LB <br /> � o zcVn = � � Do <br /> ,,, � Z D m � � � COMPRESSION LOAD. NAILING SHOWN IS TO BE USED AT MIN. <br /> Z � � � Z m Z 4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED, USE 2 x 4 SPACERS AS SHOWN. <br /> z °> D � m � � yD <br /> � W � � � p � 0 m HOLES MAY BE INSTALLED IN BLOCKING <br /> z W � � 0 � D Z � I F R E Q U I R E D P R O V I D E D T H A T <br /> � r <br /> 0 o z m� y � � n CLEARANCES SHOWN ARE MAINTAINED <br /> � ocnmr —i � D � <br /> cn -� C� O -� � <br /> � o � Z W Z O <br /> x �' C � � Z DUCT/MECHANICAL(AS REQUIRED) <br /> °' —I � N � BY OTHERS <br /> W � � � FRAMING <br /> �'' c�n �m m BY OTHERS <br /> cn <br /> cn D NAIL SHEATHING TO BLOCKING/JOISTS 0.131 f�x 3"LONG <br /> o � <br /> � w/(12)ADDITIONAL 0.131 fd x 3"LONG NAILS @ 6"O.C. <br /> NAILS SPACED EVENLY OVER 42" STRUCTURAL RIM <br /> cn o -o cn tn c� cn <br /> 3 � o y � � BOARD BY OTHERS <br /> z <br /> `� �' ° � N� n ` USP LJQ CONNECTOR <br /> o � � � o � (WIDTH TO MATCH <br /> w <br /> r BLOCKING) <br /> m � � m 1 <br /> � m N ��� � <br /> D • 2"ALL SIDES TYP � � <br /> Z ` � <br /> � �� 2x6MIN <br /> � <br /> � � � SILL PLATE <br /> o � D m <br /> w o o � I�� FOUNDATION WALL SEE <br /> j � JOISTS BY OTHERS o OTHER SHEETS FOR <br /> °' � � � ANCHORS&WALL INFO <br /> �`! PROVIDE BLOCKING AS REQUIRED TO a <br /> � � ACHIEVE NAILING SHOWN. BLOCKING HEIGHT a GRADE <br /> � c> TO MATCH JOIST DEPTH&BE OF LUMBER, � <br /> � I-JOIST,OR OTHER MANUFACTURED I I I—I IT��n--�_ <br /> �,7 � MATERIAL. ATTACH BLOCKING TO JOISTS w/ ° o��,I I I—��� <br /> (2)0.131"f�3 x 3"LONG TOE NAILS OR%6"QJ <br /> �� SCREWS EACH END TOP&BOTTOM IF REQUIRED, PROVIDE 2 x 4 MIN SPACERS <br /> 3 � SEE S12 FOR SPACING TOP&BOTTOM AT MECHANICAL UNTIL <br /> F K�� � <br /> f��o m �.. SPACES IN WHICH BLOCKING CAN BE <br /> �°'°�`" " r�� INSTALLED,TOE NAIL TO FLOOR MEMBERS w/ <br /> "V"Z`� " (2)0.131 fZ�x 3"LONG NAILS OR 3/16"PJ <br /> �;NNmm <br /> 3 m g N m a 1j� SCREWS EACH END <br />