My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00803 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2400 Fox Street - 04-117-23-41-0011
>
Permits/Inspections
>
2009-00803 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:13:27 PM
Creation date
10/19/2016 3:27:44 PM
Metadata
Fields
Template:
x Address Old
House Number
2400
Street Name
Fox
Street Type
Street
Address
2400 Fox St
Document Type
Permits/Inspections
PIN
0411723410011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� GENERAL NOTES: <br /> 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF <br /> 2250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE SUPPORTED BY THE FINAL INSTALLED <br /> FLOOR CONSTRUCTION AT BOTH THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. <br /> SHORING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. <br /> 2. STRIP FOOTINGS MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. <br /> 3. 1y" DEEP BY 3Yz"WIDE BY CONTINUOUS KEYWAYS, LOCATED ANYWHERE WITHIN THE WALL WIDTH, MAY BE USED IN <br /> LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. <br /> 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 1". A MINIMUM OF 2"OF STRIP FOOTING IS TO <br /> EXTEND BEYOND THE WALL FACE EACH SIDE. <br /> 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. <br /> 6. SLOPE GRADE DOWNWARD AWAY FROM THE STRUCTURE A MINIMUM OF 6"WITHIN THE FIRST TEN FEET UNLESS <br /> ADEQUATE DRAINS OR SWALES ARE PROVIDED. <br /> 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE,WATER-PROOFING, CONTROL JOINTS, FLASHING,AND <br /> INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED <br /> OTHERWISE. <br /> 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE.OVERALL WALL THICKNESS MAY <br /> VARY BY UP TO 1/2" FROM THAT SHOWN. <br /> 9. REINFORCING PLACEMENT TOLERANCE IS 1/2". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. <br /> MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 <br /> STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. <br /> 10. PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. <br /> HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL WIDTH AS LONG AS A MINIMUM OF 2"OF CLEAR <br /> COVER IS PROVIDED. <br /> 11. REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. <br /> 12. DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. <br /> VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5"INTO THE STRIP FOOTING IN LIEU OF DOWELS. <br /> 13. THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF FORM OIL IS PRESENT <br /> FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. <br /> 14. SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO <br /> HAVE AN ANCHOR WITHIN 4"TO 12"OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND <br /> INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A <br /> MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE <br /> REQUIREMENTS.TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. <br /> 15. SILL PLATES ARE NOT REQUIRED TO BE TREATED IN ACCORDANCE WITH IRC SECTION R319.1 ITEM 2. ANCHOR <br /> BOLTS 1/2"OR LARGER IN DIAMETER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN ACCORDANCE WITH IRC <br /> SECTION R319.3 EXCEPTION 1. <br /> 16. ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE <br /> MANUFACTURER'S REQUIREMENTS. <br /> 17. FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT NON-FIRST FLOOR BEARING FOUNDATION WALLS. <br /> Rev Date 2009 MASTER C.I.P. CONCRETE SITE ADDRESS: <br /> FOUNDATION DRAWINGS <br /> GENERALNOTES <br /> CLIENT INFORMATION: City: State: Zip: ��'.� <br /> SITE SOIL TYPE: <br /> CHARLES CUDD, LLC SAND❑ SANDYCLAY❑ c�,4v❑ <br /> 275 MARKET STREET, SUITE 445 5201 EasSuiter308 <br /> MINNEAPOLIS, MN 55405 Project Number: 08.00538 ^^ MinnT 176357752500 <br /> Drawing Date: 01-01-09 �-{ Fax 763-571-7168 <br /> Phone: 612-333-8020 Fax: 612-335-5071 Sheet: 3of16 V\�J www.ulteig.com <br /> � COPYRIGHT ULTEIG ENGINEERS INC.2009 <br />