Laserfiche WebLink
j O \ <br /> %�/ I �\� <br /> %/ \\\ <br /> �%O <br /> � <br /> i� O��\\'�\�� <br /> ��� � '' C ITY of URONO <br /> �I II <br /> �,, �, t ��� � �; <br /> ' +� �� <br /> � zY '�i , ��, ,!� Municipal Offices <br /> "� , ���{ <br /> '�� � � ' � `�.�,:�G �' Street Address �15a.-a�}�l-y6o � Mailing Address: <br /> \ �kE8H0�' 2750 Kelley Parkway P.O. Box 66 <br /> - -__= Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �S�� I'�e7� 5`�`, <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewaje treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the loca[ion,design and construction standards of flie current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or t�vo foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an unminent threat to public healtli or safety. <br /> 3 NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> o r m a y n o t m e e t a ll t h e l o c a t i o n,d e s i g n,o r c o n s t r u c t i o n s t an c h r d s o f t h e c u r r e n t O r o n o M u n i c i p a l C o d e an d w h i c h i s f a i l i n g f o r an y <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �� <br /> �T k inspection indicates: <br /> Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped_ ). <br /> Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes This allows for the proper <br /> cleanine. Keep water softner and iron filter discharee out of septic svstem to prolong life of drainfield Ask pumper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septaQe is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : ,� <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMM[�ENTS: s;�..���1 U �- S f �,� n}L � °�k V � _ <br /> \\ l�G�.:��—r.�l, �l �(i�.— (G^tJ`=c•h� �-- C`�UJ� J� S �h►'C1�fG <br /> J� � � <br /> t��5�'"_ZZ,I�� � <br /> �7 —��--�`� �.c;,,,� , — <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or othu transfer of property, be advised that this report does <br /> not guarantee or certify that an e�cisting system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> c�nditinns ha.ced nn the availahle inf�rmaN�n <br />