My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ordinance/sewage disposal
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1840 Fox Street - 03-117-23-42-0008
>
Misc
>
ordinance/sewage disposal
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:06 PM
Creation date
10/17/2016 3:22:55 PM
Metadata
Fields
Template:
x Address Old
House Number
1840
Street Name
Fox
Street Type
Street
Address
1840 Fox St
Document Type
Misc
PIN
0311723420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Municode Page 8 of 12 <br /> buildings <br /> and buried <br /> pipes <br /> Lawn 10 10 <br /> sprinkler <br /> s stems <br /> b� Sewage tanks. The minimum sewage tank size requirements are as follows: <br /> Number Tank's �iquid Capacities <br /> f (galtons) <br /> Bedroom <br /> or less 1,000 + 1,000 re ardless of arba e dis osal use <br /> 5 or 6 1,250 + 1,000 re ardless of arba e dis osal use <br /> 7, 8 or 9 1,500 + 1,500 re ardless of arba e dis osal use <br /> 10 or Sewage tanks shall be sized as other establishments per Minnesota Rules chapter 7080. <br /> more <br /> �� Pumping stations. In order to standardize installation and electrical connection <br /> methods, the foliowing pumping station requirements must be met in addition to <br /> Minnesota Rules chapter 7080: <br /> �• Electrical connection. <br /> �� A watertight, lockable electrical box must be mounted on a four- <br /> inch-by-four-inch treated redwood or cedar post. <br /> ��� All electrical connections shall be made within the box. Pump <br /> connection must not be made using a direct line (plug-in only). <br /> Wire entry to the electrical box shall be sealed with a watertight <br /> material such as foam or putty. <br /> iii. Alarm and pump floats shall be on separate electrical circuits. <br /> iv. Electrical wire from the power supply must not run over any tanks <br /> but must be laid beside the tanks and placed in conduit along the <br /> electrical post. <br /> �� Electrical cords from the pump and floats must be run through a <br /> two-inch PVC (or equivalent) conduit (schedule 80) with a one- <br /> inch gap between the conduit and the electrical box. Electrical <br /> cords must not run through or under the manhole cover. Wires <br /> must not have ground contact. <br /> 2� Pumping chamber. <br /> �� Pressure pipe exiting the pumping chamber must be laid on a <br /> uniform slope up to the soil treatment area for proper drain back. <br /> The pressure pipe must be sleeved inside a larger diameter pipe <br /> for additional support if spanning ground that has been <br /> excavated. If the pipe at the tank must be lower than union to get <br /> elevation for drain back, a one-quarter-inch weep hole must be <br /> used. <br /> ii. <br /> https://library.municode.com/print.aspx?h=&clientl D=13094&HTMRequesrhttps%3a%2f%2flibrary.municode.com%2fI IT... 6/24/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.