2012-00781 - new mound system
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1925 Fox Street - 03-117-23-43-0002
>
Septic
>
2012-00781 - new mound system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:32 PM
Creation date
10/17/2016 1:36:17 PM
Metadata
Fields
Template:
x Address Old
House Number
1925
Street Name
Fox
Street Type
Street
Address
1925 Fox St
Document Type
Septic
PIN
0311723430002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•version • Troy.Johnson(c�co.Wright.mn.us <br /> ' 2,p Mou n Des�gn for questions or comments <br /> Property Owner: Joann Watson Date: 6l28/2012 <br /> Site Address: 1925 Fox St., Orono PID: <br /> Comments: <br /> instructions: � = req'd input � =input or default � =calculated field 't' = instalter info <br /> t� �4 bedroom Type � Residential System <br /> 2) 600 GPD design flow <br /> 3> No Garbage disposal or pumped to septic <br /> a� *** 200Q Galton septic tank(minimum) Multiple tanks or compartment req'd <br /> s� 1.2 GPD/ftZ mound sand loading rate <br /> 6� 10 ft rockbed width 50.0 ft rockbed length <br /> �� '�"" 3.0 ft tatera[spacing 3.0 ft perforation spacing {default 3, range 2-3, for both) <br /> end feed manifold connection <br /> a} ***�laterats 48.0 feet long 17 perfs / lateral 51 perfs total <br /> 9� �""� 1/4" inch perfs at �1 feet residuat head gives 0.74 gpm flow rate per perforation <br /> (3/16"default) (2'head defautt) <br /> for this perf size f�spacing, �t pipe size on tine 12, max perfs/lateral= 25 , tine#8 must be tess --> OK <br /> lo� �4 doses per day (5 recommended, 4 minimum) (4 will atlow 2" taterals, 5 will allow 1.5") <br /> i�� 150 galtons per dose (treatment volume) <br /> iz� 2.00 inch diameter laterals (or smalter) will meet"5x pipe volume" <br /> '*' 2.00 inch diameter laterals (or smallerj must be used to meet"4x pipe volume" requirement <br /> 2.00 inch diameter laterals (or smaller)will meet"3x pipe volume" <br /> �3� !"* 20 feet of 2.0 inch supply line leads to �galtons of drainback volume <br /> ("top feed"manifotd to control the drainback) <br /> ia� 153 gatlons TOTAL pump out volume (treatment+ drainback) <br /> ts) 10 feet vertical lift from pump to dispersal area, teads to a: <br /> i6� '** 38 GPM C� 16 feet of head, Pump requirement note: >50gpm may require an extra 3-6'of head <br /> »� *** 1000 gal Dose tank (minimum) at approximately 25.00 gpi <br /> leads to a <br /> la� '** 6.1 inch swing on Demand float, or timed dosing of 4 min ON (confirm pump rate with drawdown <br /> (<100%of design ftow requires a larger OFF time} 5.9 hrs OFF test and adjust as necessary) <br /> ►9> 12 inches from bottom of tank to"pump OFP'float, and/or to cover pump <br /> Zo� *'* 18 inches from bottom of tank to"pump ON"float, or 15 inches to"timer ON"float <br /> 2» *'* 21 inches from bottom of tank to"Hi Levet"float (add 5-15 inches if Time Dosed) <br /> z2� 475 gallons reserve capacity (after High Level Atarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.