My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00625 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1880 Fox Street - 03-117-23-42-0015
>
Permits/Inspections
>
2009-00625 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:22 PM
Creation date
10/17/2016 1:13:54 PM
Metadata
Fields
Template:
x Address Old
House Number
1880
Street Name
Fox
Street Type
Street
Address
1880 Fox St
Document Type
Permits/Inspections
PIN
0311723420015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�Carrier Sample Project Title <br /> GeoDesignEr� 9/9/20fl9 Page 1 <br /> �Project Information <br /> Prepared For: Prepared By: <br /> Mr. and Mrs. Sample Customer Sampie Heating and Cooling <br /> 1234 Sample Drive 555 W. Demo Road <br /> Sample City, USA 12345 Anywhere, USA 469825 <br /> 123-321-1234 555-1212 <br /> 123-321-1234 555-1212 <br /> Notes: Sample Customer Note Notes: Sample Dealer Note <br /> 'Design Data <br /> Heating Load: 180,000 Btu/Hr Heating Setpoint: 70 Deg F <br /> Htg Load Temp Diff: 80 Deg F Cooling Setpoint: 75 Deg F <br /> Cooling Load: 72,100 Btu/Hr Begin Cooling At: 70 Deg F <br /> Clg Load Temp Diff: 25 Deg F Hot Water Setpoint: 130 Deg F <br /> Sensible Cooling: 65,000 Btu/Hr Hot Water Users: 4 <br /> Continuous Fan: No <br /> Reference City: Minneapolis, MN <br /> Winter Design: -12 Deg F Annual Heating: 334.2 Million Btu � <br /> Summer Design: 92 Deg F Annual Cooling: 50.7 Million Btu <br /> Bldg Balance Temp: 57 Deg F Annual Water Heating: 22.1 Million Btu <br /> Avg Internal Gains: 28,722 Btu/Hr Daily Hot Water Use: 70 Gallons <br /> �Estimated Operating Cost Summary <br /> System Heating Cooling Hot Water Constant Total Per <br /> Cost Cost Cosi Fan Cost Month <br /> 2-5 ton split geo units. $1,550 $72 $143 $0 $1,765 $147 <br /> No Option Selected $0 $0 $0 $0 $0 $0 <br /> No Option Selected $0 $0 $0 $0 $0 $0 <br /> Comments: Utility Cost Rate Summer Winter <br /> Sample Project Note. Electric- Geothermal $/kwh .045 .045 <br /> Electric- Heat Pump $/kwh 045 .045 <br /> Electric- Furnace $/kwh 097 .097 <br /> Natural Gas $/therm 1.00 1.00 <br /> Sample Proj # Propane $/gallon 2.50 2.50 <br /> Fuel Oil $/ allon 2.50 2.50 <br /> Due to the variability of weather, system installation, and living habits this analysis is to be considered an estimate. <br /> 919/09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.